Troubleshooting guide
UV and conventional coatings on glass, metal, plastic, board, concrete and wood: what stops a line, and what to check first.
Uniform Industries · Greater Noida, India · ufindustries.com
Figures are typical for the class and carry their test method. The values that govern a supply are those on the Technical Data Sheet for the grade.
Before you start
Work down the page. Cheap checks before expensive ones, and measure before you change anything.
01
What happens, in order, and the one variable held at each step.
The process
Control variables
| Variable | Target | How it is measured | How it drifts |
|---|---|---|---|
| Substrate wetting and surface energy | Glass and ceramic: a continuous water break free film for 30 s after rinsing. Plastics: 38 mN/m minimum, 42 to 46 mN/m for hard coats on PC and PMMA. Metal: no water break on the degreased panel. | Water break test on glass and metal. On plastics, wetting tension with test inks or dyne pens applied to the part about to be coated, not to a retained sample; state which system is used, because pens and inks do not read alike. Cite ASTM D2578 only where it applies, which is polyethylene and polypropylene film; on rigid mouldings in PC, PMMA and ABS treat the ink reading as a floor check and confirm with contact angle to ASTM D7334 when a number has to go into a specification. | Falls through a shift as degreaser bath loading rises and as treated plastic parts sit in stores. Corona and flame treatment decay over days; slip and mould release additives bloom back to the surface within a week. The first parts of the morning are usually the best parts of the day. |
| Steel preparation: blast grade, profile and soluble salts | Blast grade to the specification for the system, typically Sa 2.5 to ISO 8501-1 for an industrial build, with the profile inside the grade's stated range measured to ISO 8503. Soluble salt level to the limit agreed for the service condition; a few tens of mg/m2 of chloride is already too much for immersion or condensing service. | Blast grade judged against the ISO 8501-1 pictorial standards in the booth light. Profile by comparator or replica tape to ISO 8503, recorded per batch. Soluble salts by Bresle patch to ISO 8502-6 with conductivity to ISO 8502-9, at least three patches per batch and at least one on a weld or a corner where washing is worst. | Salt comes back with every wet or coastal delivery, with re-used abrasive and with handling. A blasted surface flash rusts within hours at high humidity, and abrasive that is recycled without separation carries salt from one job into the next. |
| Application viscosity | Spray 16 to 25 s, dip and flow coat 16 to 30 s set on the part, curtain 25 to 45 s, roller coat 30 to 60 s and often higher on a thixotropic grade, all on a 4 mm cup at the stated temperature. Flow coat floods the part and relies on the excess draining off, so it runs near dip viscosity, not at roller viscosity. Dip work is set on the part, not on the cup, then logged as a cup reading. | State the cup and the standard separately. The house cup is a DIN 4 mm cup to DIN 53211, sample and cup both at 25 +/- 1 C, calibration checked monthly. An ISO flow cup with a 4 mm jet is to ISO 2431 and does not give the same number, and ISO 2431 specifies 23 +/- 0.5 C, so where the house condition is 25 C record it as an agreed deviation; efflux time moves roughly 2 to 3 % per degree. Ford cups are to ASTM D1200 and Zahn cups to ASTM D4212. A target set on one cup is re-established on the other, never converted on the floor. | Rises over a shift as solvent flashes from an open pan and as the circulation pump puts work into the coating. A UV coating shear thins in the pump and reads low while running, then reads high when sampled cold. Sample from the same point every time. |
| Coating and part temperature | Coating 25 +/- 2 C at the applicator. Part within 5 C of the coating. | Contact or infra-red thermometer on the coating in the pan and on the part as it enters the applicator. Log both at the start, middle and end of a run. | Climbs steadily on a circulating system: pump work, lamp infra-red radiating back and hall temperature all add. A cold part out of stores in winter pulls viscosity up locally and gives orange peel on the first hour's work only. |
| Film weight or dry film thickness | Glass and plastic hard coats 3 to 8 micron dry. Metal decorative coatings 8 to 25 micron dry. Board coating 2.0 to 3.5 g/m2. Wood sealer 8 to 20 g/m2 and topcoat 6 to 12 g/m2 per pass. Concrete 60 to 200 micron per coat. | Wet film comb on the wet film, dry film by magnetic or eddy current gauge to ISO 2808 on metal, and by weighing a cut area of coated against uncoated stock on board. Calibrate the gauge on the same substrate class. | Climbs as viscosity climbs and as roller nip or curtain slot settings move under heat. Falls as a spray nozzle wears open and the pattern widens. Edges, radii, holes and weld crowns always carry less than the flat face, because surface tension pulls the film back from an edge while it is still liquid, and that is where corrosion and chemical attack start. |
| UV dose at the part surface | Indicative for this class: 200 to 500 mJ/cm2 for a clear industrial coating, 400 to 800 mJ/cm2 for a pigmented or heavy film, measured in the band the lamp actually emits. | Band matched radiometer carried through the line at running speed, on a fixture that puts the head where the worst part face sits. Match the head to the source: a UV-A head for a mercury arc or a 385 nm array, and a UV-V head, roughly 395 to 445 nm, for 395 and 405 nm arrays, because the UV-A band ends at 400 nm and under-reports them. A broadband head calibrated for a mercury arc will not report what an LED array delivers. Record the instrument, the head band and its calibration date with every trace. | Falls with lamp hours, dirty quartz, a tarnished reflector and a dusty LED window, long before anything looks different. On a three dimensional part the dose varies by a factor of three between the face and the side, and that variation is the real process window. |
| Oven cure: peak metal temperature and time at temperature | To the grade's schedule, quoted as peak metal temperature and minutes at that temperature, not as an oven set point and a conveyor time. A typical industrial stoving schedule sits in the range 140 to 200 C peak metal temperature for 10 to 20 min at temperature; the grade's own data sheet governs. | Oven profile with a multi-channel data logger travelling with the part, thermocouples attached to the heaviest section, the lightest section and a shadowed face. Record the ramp, the peak and the time above the stated temperature. Profile again after any change to loading, line speed, burner or extraction, and at least twice a year. | Moves with load density, with part mass, with extraction balance and with burner condition. A heavy rack shields its own centre, so the part in the middle of the load is the one that under-bakes while the controller reports the set point it was given. |
Control variables
| Variable | Target | How it is measured | How it drifts |
|---|---|---|---|
| Two-pack ratio and pot life | Hardener or silane addition to the ratio on the label, weighed. Pot life is grade specific and is taken from the product data sheet, commonly 2 to 8 h at 25 C, with hydrolysed silane primers at the short end and 2K isocyanates at the long end. Assume it roughly halves for every 10 C rise: a mix with 8 h at 25 C has about 4 h at 35 C and about 2 h at 45 C. | Weigh both components on a bench balance, do not use a ladle or a mark on a bucket. Take pot life from the data sheet and from the clock: write the mix time on the pot in marker and discard at the stated time whether or not the material still looks usable. Viscosity rise is a late and unreliable end point, and on a silane system it never arrives, because the mix can lose all of its reactive silane with no measurable change in cup time. Where a viscosity criterion is used at all on an isocyanate system, take it as a doubling of the initial efflux time and treat it as a back-stop, never as the control. | The reaction runs whether or not the line is running. Mixed material used beyond pot life looks and coats normally and never develops adhesion, which is why this fault surfaces at the customer rather than on the line. |
| Relative humidity, dew point margin and the coating hall | 45 to 65 % RH at 25 C for silane primed glass and ceramic work. Below 70 % RH for solvent and water borne systems in the flash zone. In every case the substrate temperature is at least 3 C above the dew point at the time of application and until the film is through the flash zone. | Calibrated hygrometer at the line, not at the office wall, with a surface thermometer on the part, and the dew point margin taken by the ISO 8502-4 procedure. Log with the shift record. | Silane hydrolysis needs ambient water; below about 35 % RH the bridge does not form in the time available and adhesion is short. Above 75 % RH a solvent coating blushes and a water borne coating will not flash. A cold part out of winter stores can sit below the dew point at a hall RH of 55 %, so hold cold parts to hall temperature before coating. Monsoon and winter behave as different processes. |
| Line speed and flash time | Set so the film levels and the carrier is out before the lamp or the oven. Typically 30 to 90 s flash for a solvent reduced UV coating; none needed for a 100 % solids system; longer again on a conventional solvent coating going to a bake. | Time a marked part from applicator to lamp or oven with a stopwatch. Confirm the carrier is out by weighing a test panel before the cure stage. | Speeding the line cuts flash time and dose together, and the two faults look different on the part: retained solvent shows as blisters, pop and soft film, low dose as a tacky surface. |
| Circulation system cleanliness and light exclusion | No stray daylight or lamp light on the pan, the hoses or the header tank. Feed filtered to a rating set by the finish: typically 25 to 50 micron absolute for spray and thin hard coats, 50 to 100 micron for roller, curtain and heavy builds, with nominal or absolute stated on the specification. A coarser strainer on the return as well. | Find stray light in two safe passes. First, with the lamps off and the hall lights off, look for daylight ingress on the pan, the hoses and the tank, from roof lights, doors and translucent panels. Second, with the lamps on and all guarding, shutters and extraction in their normal running state, do not look at the lamp house: lay UV sensitive indicator cards or a photodiode probe on the pan lid, the hoses and the tank top and read them afterwards. Anyone inside the line while lamps run wears a UV face shield and UV blocking eyewear with skin covered, and the ozone extraction is confirmed running first. Check both filter baskets each shift and keep the removed material. | Gel particles build slowly, then appear all at once as seeds and craters. A rising catch of soft gel in the return strainer is the earliest warning you get. A UV coating that has gelled cannot be thinned back; it is discarded. |
The mechanism
The most misunderstood point in this category is that adhesion to an inorganic substrate is a wet interface problem, not a dry one. A coating held by physical forces alone passes every test you can run on day one and fails as soon as water reaches the interface, which is why the silane bridge and the humidity test both exist. Read the four panels left to right: the surface you are actually coating, what happens with physical adhesion only, what the silane bridge changes, and what the test schedule therefore has to be.
02 | 20 faults
Symptom, cause, check, change, confirm. The trap is the move to avoid.
Fault 1 of 20
WHAT YOU SEE
Small round craters with a raised rim, often with a speck at the centre, or the coating pulling back into islands and leaving bare substrate. It is usually worse on one rack position, one fixture or one side of the part.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 1 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Twenty consecutive parts through the full line with no crater visible at the inspection station: at least 1000 lux at the part, 1000 to 2000 lux being the working range, with a grazing low angle or specular light, the part turned through the reflection, at a fixed viewing distance and at the same station every time. Plus a water break free result on the cleaned substrate on the same shift. If a flow additive was used, confirm overcoat adhesion by ISO 2409 cross-cut on a topcoated part.THE TRAP
Adding more flow additive or more solvent to make the coating level. It closes the craters on the next few parts and puts a low surface energy layer through the whole batch, which then fails intercoat adhesion under the topcoat and craters worse once the additive is consumed.Fault 2 of 20
WHAT YOU SEE
The part passes a tape test at the end of the line and fails days later, after a humidity cabinet, a dishwasher cycle or a warm store. The coating comes away cleanly, with no coating left on the glass.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 2 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Cross-cut to ISO 2409 at class 0 or 1 after 24 h conditioning to ISO 6270-2 at 40 C, tested within 30 min of removal and again after 24 h recovery, both results recorded, on the customer's own glass, plus the customer's own wash or dishwasher cycle where that is the service condition. Adhesion on glass is a property of the customer's glass, its cleaning and this coating together, so it is qualified on their material every time the glass source changes.THE TRAP
Testing adhesion at the end of the line, passing, and shipping. A physically adhering film always passes on day one. The test that means anything is run after the interface has seen water, and it is read while the film is still wet from the cabinet as well as after it has dried back, because a re-dried film can recover a pass it did not deserve.Fault 3 of 20
WHAT YOU SEE
A thumb twist marks the surface, parts block or fingerprint in the stack, and dust sticks to the face while the body of the film is fully hard when scraped.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 3 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No mark from a firm thumb twist immediately off the line, 50 or more MEK double rubs to ASTM D5402 on the worst face, and the radiometer pass inside the specified dose and peak irradiance window on that same face.THE TRAP
Slowing the line. More time at low irradiance gives oxygen more time to quench the surface, so the tack often gets worse while the operator watches the dose reading go up.Fault 4 of 20
WHAT YOU SEE
The surface is hard and glossy but the coating can be lifted whole with a blade or a strip of tape, and the underside is soft or smells of monomer. Common on whites, heavy colours and anti-corrosion grades on steel.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 4 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Cross-cut to ISO 2409 at class 0 or 1 at 24 h with no whole film lift, 50 or more MEK double rubs to ASTM D5402, no monomer odour from the underside of a deliberately removed film, and a radiometer reading inside the window on the worst face.THE TRAP
Reaching for more film weight when the colour looks weak. Opacity and cure pull in opposite directions on a pigmented coating; the heavier film hides the colour problem and creates an adhesion failure that arrives at the customer three weeks later.Fault 5 of 20
WHAT YOU SEE
The two-layer system delaminates cleanly between the layers; the basecoat is still firmly attached to the part and the topcoat comes off as a sheet or in flakes at the cross-cut.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 5 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Cross-cut to ISO 2409 at class 0 or 1 at 24 h on the full two-layer build, and, where the failure plane has to be established as a reportable result, pull-off to ASTM D4541 on a flat panel of the same substrate and the same build, with the failure mode recorded as cohesive in the basecoat, adhesive at the base to topcoat interface, or adhesive at the base to part interface. ISO 2409 classifies the area of flaking and does not report a failure plane, so the loupe observation is a guide and the pull-off is the record. Accept cohesive failure in the basecoat; reject failure at the interlayer. No delamination after the humidity or thermal cycle the job specifies.THE TRAP
Raising the basecoat dose because the base feels soft. A harder base is a worse key, so the delamination gets cleaner and more complete while every individual layer measures well.Fault 6 of 20
WHAT YOU SEE
Curtains and tear drops on the vertical faces of a part, a thick lower edge, and a build up at the bottom of a dipped part. The flat faces look right.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 6 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Twenty consecutive parts with no sag visible at the inspection station, at least 1000 lux at the part with a grazing low angle light, wet film within the specified band on both vertical and horizontal faces, and viscosity logged inside the window at the start and end of the run.THE TRAP
Thickening the coating with an additive or with a different batch to stop the run. It stops the sag and starts orange peel and poor edge coverage, and it usually pushes film weight up again, which was the real cause.Fault 7 of 20
WHAT YOU SEE
A regular dimpled texture over the whole face, or fine parallel lines running in the machine direction, most visible on a gloss finish and under a low angle light.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 7 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Gloss to ISO 2813 at 60 degrees within 3 GU across the width and within the grade's specification, and no texture visible at the inspection station under a grazing low angle light at 1000 lux or more at the part, on twenty consecutive parts.THE TRAP
Thinning the coating with solvent or monomer to make it level. The texture improves and film weight, hardness and chemical resistance all fall with it, so the part then fails the MEK rub test that nobody re-ran.Fault 8 of 20
WHAT YOU SEE
Small open holes or burst bubbles over the whole coated face, worst on machined MDF edges, open grain and porous concrete, and worse on the first coat than on later coats. On a non-porous part, see solvent pop instead: the cause is different.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 8 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No pinholes visible at the inspection station under a grazing low angle light at 1000 lux or more at the part, on twenty consecutive parts including machined edges, substrate moisture logged inside the window before coating, and specified adhesion and hardness maintained on the two-pass build.THE TRAP
Applying a heavier topcoat to fill the pinholes. The extra weight traps more air and makes the boil worse, and the heavier film then under-cures at its base as well.Fault 9 of 20
WHAT YOU SEE
Small open craters or burst bubbles over the face of a baked part, worst where the film is thickest and on the face that meets the burner or the radiant panel first. The substrate is not porous, the film below the crater is sound, and the same job runs clean when the oven is loaded lightly.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 9 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No craters visible at the inspection station at 1000 lux or more at the part on twenty consecutive parts, an oven profile logged on the part with peak metal temperature and time at temperature inside the grade's window on the lightest, heaviest and most shadowed positions in the load, and film weight to ISO 2808 inside specification on the same parts.THE TRAP
Turning the oven up to drive the solvent out faster. A hotter front zone skins the film sooner, so the pop gets worse while the recorded bake looks better, and the extra heat at peak embrittles the film that did survive.Fault 10 of 20
WHAT YOU SEE
The falling curtain tears open, or runs with fine vertical lines that print as machine direction stripes on every part until the curtain is reformed.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 10 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
A stable curtain for the full length of a run with no tear, no vertical line visible on the coated face at the inspection station under a grazing low angle light at 1000 lux or more at the part, and film weight within specification across the full width measured at five points.THE TRAP
Opening the slot or raising the flow to hold the curtain together. It covers the fault for a while, puts film weight up, and turns a streak problem into a sag and under-cure problem at the same time.Fault 11 of 20
WHAT YOU SEE
A sandy or matt patch on an otherwise glossy part, usually at the edges of the fan, on the far side of the part from the gun and on the parts nearest the extraction. It feels rough under the hand and gloss reads low; the loose version lifts with a fingernail, the trapped version does not.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 11 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No rough or matt deposit felt by hand or visible at the inspection station at 1000 lux or more at the part on twenty consecutive parts, gloss to ISO 2813 at 60 degrees within 3 GU of the retained standard at five points, and gun distance, tip and pressure recorded on the setting sheet.THE TRAP
Adding retarder at the gun to stop the dry spray. It cures the roughness for an hour and puts sags, soft film and slow through-cure into the same batch, and nobody records how much went in.Fault 12 of 20
WHAT YOU SEE
Fine cracks along a bend, at a swage or around a fixing hole, or a crazed pattern appearing after the part has been through hot and cold cycles. The coating itself is hard and passes every resistance test.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 12 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No cracking visible at 10x after the mandrel bend at the service radius, after ten thermal cycles across the service range, and cross-cut to ISO 2409 at class 0 or 1 on the bent area 24 h later. Formability is a property of the coating and the customer's substrate and forming operation together, and it is qualified on their own parts.THE TRAP
Curing harder to make the coating tougher. A harder film is a more brittle film; increasing dose on a cracking part reliably makes the cracking worse while every hardness reading improves.Fault 13 of 20
WHAT YOU SEE
The first parts of the day and the last parts do not match under the light box, or one rack position is consistently duller. Matt grades drift more than gloss.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 13 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Gloss to ISO 2813 within 3 GU of the reference standard at 60 degrees, at five points per part, on the first, middle and last parts of the run, with film weight logged inside the window at the same three points. Where 20 degrees or 85 degrees is the reporting geometry, widen the band to about 5 GU to match the method's reproducibility and state the geometry with the figure.THE TRAP
Adjusting film weight to bring the gloss back. It corrects the reading and moves hardness, chemical resistance and cure through depth with it, so the batch that matches the standard is the batch that fails the resistance test.Fault 14 of 20
WHAT YOU SEE
The coating applies, flows and cures normally and the parts look correct, but cross-cut adhesion after humidity is poor on the afternoon's work and good on the morning's.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 14 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Cross-cut to ISO 2409 at class 0 or 1 after 24 h conditioning to ISO 6270-2 at 40 C, tested within 30 min of removal and again after 24 h recovery, on parts taken from the start and from the last hour of each pot, with the mix time, the hall temperature and the weighed ratio in the shift record.THE TRAP
Adding a little more hardener to an old pot to wake it up. The pot life has already been consumed by the reaction, and the extra hardener only adds free material that blooms to the surface and takes overcoat adhesion with it.Fault 15 of 20
WHAT YOU SEE
The cup reading rises hour by hour, film weight creeps up with it, and eventually seeds and soft gel lumps appear in the filter or as craters on the part.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 15 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Viscosity on a DIN 4 mm cup to DIN 53211 at 25 +/- 1 C within 3 s across an eight hour run, a clean filter basket and return strainer at the end of the shift, and no seeds or craters on the last twenty parts.THE TRAP
Thinning the tank back to the target cup reading. Gel is not reversible; thinning disperses partly polymerised material through the batch, so the parts look acceptable while film weight, hardness and cure are all now wrong, and the seeds come back within the hour.Fault 16 of 20
WHAT YOU SEE
Fine surface crazing on a clear part, a warped or dished panel, or cracks appearing at mould gates, ribs and fixing bosses days after coating. Polycarbonate, acrylic and ABS are the usual sufferers.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 16 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No crazing visible at 10x at 48 h on twenty parts, flatness within the customer's drawing tolerance, and cross-cut to ISO 2409 at class 0 or 1 at 24 h. Compatibility is a property of the customer's moulding, its polymer grade and its moulding stress together, and it is qualified on their own parts before a production run.THE TRAP
Blaming the coating and slowing the line under a mercury lamp to get more dose. Slower means longer under the infra-red, so the part gets hotter, the distortion gets worse, and the stress cracking arrives faster.Fault 17 of 20
WHAT YOU SEE
Small domed blisters, sometimes with liquid inside, and rust spreading back from a scribe, a chip or an edge far faster than the salt spray result suggested. It appears weeks or months after a batch that passed every test on the line, and the pattern follows the steel and the blast batch, not the applicator or the rack.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 17 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Bresle conductivity to ISO 8502-9 inside the agreed limit on at least three patches of the prepared surface, blast grade and profile recorded to ISO 8501-1 and ISO 8503, substrate at least 3 C above dew point at the time of coating to ISO 8502-4, and neutral salt spray to ASTM B117 rated to ASTM D1654 against the agreed hours, run on the customer's own steel with their own preparation. Corrosion performance is a property of the customer's steel, its preparation, its edges and welds and this coating together, and it is qualified on their parts.THE TRAP
Coating over flash rust or over a salt contaminated surface because the blast booth is committed and the line is waiting. The parts look right, pass the tape test and pass at goods inward, and the cost arrives months later as a whole batch of blistered work that has to be stripped.Fault 18 of 20
WHAT YOU SEE
A white or clear finish going yellow within weeks indoors or months outdoors, or an exterior part losing gloss and powdering at the surface when wiped.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 18 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Delta b and delta E measured against the retained standard after the agreed accelerated weathering exposure on the customer's own substrate, within the limit written into the specification, with a control panel run alongside. We state the formulation and the class of stabilisation used; service life is qualified on the customer's part in their own exposure.THE TRAP
Treating yellowing as a colour problem and re-matching the white a little bluer to cover it. The shift continues, the part goes green before it goes yellow, and the underlying cause, which is usually cure or the wrong chemistry for the exposure, is now hidden behind a special shade nobody can reproduce.Fault 19 of 20
WHAT YOU SEE
The part passes the solvent rub test at the line and fails at the customer after cleaning fluid, hand sanitiser, sun cream, oil or a detergent wash. The film may soften, swell, go matt or lift entirely.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 19 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
50 or more MEK double rubs to ASTM D5402 at 24 h and 100 or more at 7 days for a two-pack build, plus a pass on the customer's own reagent at their own concentration, contact time and temperature. Chemical resistance is a property of this coating on the customer's substrate at their film weight, and it is qualified on their parts.THE TRAP
Running the MEK rub at the end of the line, getting a pass and releasing. The film is still developing, and a pass at one hour tells you the surface cured, not that the network is finished.Fault 20 of 20
WHAT YOU SEE
Domed blisters, sometimes with water underneath, or whole sheets lifting weeks after application, often in patches that follow the slab rather than the application pattern.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 20 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Pull-off adhesion to ASTM D4541 above 1.5 MPa, or failing in the concrete rather than at the interface, on at least three test patches on the actual slab, with the slab relative humidity recorded to ASTM F2170 against the limit in the specification before application. Floor adhesion is a property of the customer's slab, its age, its preparation and its moisture condition together with this coating, and it is qualified on their floor.THE TRAP
Sealing over a blistered area with more coating. The vapour pressure driving the blister is still there, so the repair lifts too, and the extra film makes the next blister larger and harder to see coming.03
One page to work from, and the methods behind every number.
Quick reference
| Symptom | Check this first | Change this first |
|---|---|---|
| Craters, fisheyes, coating pulls back | Water break test on the cleaned substrate; blow the spray air onto a mirror | Fix the cleaning stage and the compressed air, not the coating |
| Passes tape test, fails after humidity | Mix time on the pot against the clock; the glass wash and the glass batch | Mix fresh inside pot life; clean the glass properly and re-test after conditioning |
| Tacky face, hard body | Is the grade specified for the lamp fitted, mercury or LED; then lamp hours and quartz | Correct the grade or the lamp; clean quartz and reflector and close the lamp to part distance |
| Whole film lifts off, underside soft | Dry film thickness to ISO 2808 and lamp type on that station | Reduce film weight; move white to a gallium doped or 405 nm source and read it with a UV-V head |
| Topcoat peels off the basecoat | Basecoat dose and the interval between coats against the recoat window | Cut basecoat dose to a partial cure; shorten the interval |
| Sags and runs on vertical faces | DIN 4 mm cup to DIN 53211 at 25 C at the applicator and dwell time to the lamp | Cool the coating to 25 C; shorten the dwell before the lamp |
| Orange peel or machine direction ribbing | Cup reading at 25 C and part temperature entering the coater | Warm the parts to within 5 C of the coating |
| Pinholes on wood, MDF edge or concrete | Substrate moisture meter, or ASTM F2170 probes equilibrated 24 h in a slab | Seal first and cure it; split the build into two lighter passes |
Quick reference
| Symptom | Check this first | Change this first |
|---|---|---|
| Craters in a baked film on a non-porous part | Oven profile logged on the part, first two minutes of the ramp | Lower the front zone and lengthen the flash before the oven |
| Curtain tears or shows vertical streaks | Slot lip and edge guides under a torch; foam in the return | Clean the lip and guides; screen the curtain from draughts |
| Sandy matt patches and overspray dust | Gun to part distance and hall temperature at the booth | Bring the gun to the standard distance; move to the slower thinner blend |
| Cracks at a bend or after thermal cycling | Dry film thickness at the bend; time since cure | Reduce film weight and hold 24 h before forming |
| Gloss or matt level drifting through the shift | ISO 2813 at 60 degrees, five points, start and end of run | Agitate the matt grade continuously; lock coating temperature |
| Cup reading climbing hour by hour | Daylight ingress with the lamps off, then indicator cards on the pan with the lamps guarded and running | Black out and shield the loop; fit a heat exchanger at 25 C |
| Clear plastic part crazing or warping | Part surface temperature straight after the lamp or the array | Move to LED, or fit dichroic reflectors and cooling, and re-measure the part temperature |
| Blisters and rust creep on steel weeks later | Bresle patch to ISO 8502-6 and conductivity to ISO 8502-9 on the prepared steel | Wash or wet blast the prepared surface and re-test before coating |
Quick reference
| Symptom | Check this first | Change this first |
|---|---|---|
| Resistance fails at the customer, passed here | MEK double rubs at 24 h and at 7 days on the same batch | Hold two-pack parts 7 days before release testing |
Test methods
| Measurement | Method | What it tells you, and the usual acceptance |
|---|---|---|
| Cross-cut adhesion | ISO 2409 | A lattice cut through the film to the substrate, tape applied and removed, classified 0 to 5, with the cut spacing set by the film thickness: 1 mm for films to 60 micron on a hard substrate, 2 mm for 61 to 120 micron, 3 mm for 121 to 250 micron. The method is not valid above 250 micron, so heavy concrete and floor builds go to pull-off instead. Target class 0 or 1 at 24 h on rigid substrates, then repeat after humidity conditioning, because a physically adhering film passes at day one. Not used on very thin films over soft substrates, where the blade cuts the substrate rather than the coating. |
| Humidity conditioning before adhesion testing | ISO 6270-2 (or ASTM D2247 / ASTM D4585) | 24 h at 40 C constant condensation is the house condition; where a cabinet is set to 40 C and 95 % RH instead, record that as the house condition rather than citing it as the standard. Test within 30 min of removal and again after 24 h recovery, and record both, because a re-dried film can recover a pass it did not deserve. Where the service condition is a wash, a boil or a dishwasher cycle, run the customer's own cycle as well. |
| Pull-off adhesion | ASTM D4541 | A dolly bonded to the coating and pulled normal to the surface with a portable tester, reported in MPa with the failure mode stated. The house method for concrete, heavy metal coatings and any case where the failure plane has to be a reportable result, run on a flat panel or a flat area of the same substrate and build. On concrete, above 1.5 MPa, or failure inside the concrete itself, is the usual acceptance; the failure mode matters more than the number. |
| Solvent double rubs | ASTM D5402 | Methyl ethyl ketone on a cloth under a defined load, rubbed until the coating softens or the substrate shows. Reports cure state, not adhesion. Typically 50 or more for a cured industrial clear at 24 h and 100 or more for a two-pack build at 7 days. Always report the load, the cloth and the stroke length with the number. Run it under local exhaust or in a fume cupboard, away from lamps, heaters and any other ignition source, with eye protection and butyl rubber or laminate film gloves: MEK has a flash point near minus 9 C, an eight hour exposure limit of the order of 200 ppm, and it permeates nitrile within minutes, so the line glove is not suitable for this test. Keep the solvent in a closed, labelled, earthed container and put used cloths in a lidded metal bin. |
| Flow cup viscosity | DIN 53211 (DIN 4 mm cup); ISO 2431 (ISO flow cup, 4 mm jet); ASTM D1200 (Ford); ASTM D4212 (Zahn) | Efflux time in seconds, with the cup and the standard quoted together. A DIN 4 second is not an ISO 2431 second, a Ford B4 second or a Zahn 2 second, and a target set on one cup is re-established on the other rather than converted. ISO 2431 specifies 23 +/- 0.5 C; the house condition of 25 +/- 1 C is recorded as an agreed deviation, because efflux time moves roughly 2 to 3 % per degree. Spray 16 to 25 s, dip and flow coat 16 to 30 s, curtain 25 to 45 s, roller coat 30 to 60 s and above. Readings taken at whatever the hall happens to be are the commonest reason a finish drifts across a shift. |
| Film thickness | ISO 2808 | Dry film by magnetic gauge on steel and eddy current on aluminium, calibrated on the same substrate class; wet film by comb at the applicator; on board and paper by weighing a cut area of coated against uncoated stock. Measure edges, holes and weld crowns as well as the flat face, because they always carry less. Typical builds: 3 to 8 micron on glass and plastic hard coats, 8 to 25 micron on decorative metal, 2.0 to 3.5 g/m2 on board. |
| Specular gloss | ISO 2813 | 60 degrees as the standard geometry, 20 degrees for high gloss and 85 degrees for matt. Five points per part, judged against a retained reference standard kept at the line. Acceptance typically within 3 GU of the standard at 60 degrees; widen to about 5 GU at 20 degrees on a high gloss and about 5 GU at 85 degrees on a deep matt to match the method's reproducibility, and state the geometry with every acceptance figure. Gloss on a porous substrate is a property of the substrate and the coating together, so it is re-qualified when the substrate changes. |
Test methods
| Measurement | Method | What it tells you, and the usual acceptance |
|---|---|---|
| Hardness and abrasion | ASTM D3363 pencil hardness; ASTM D4060 Taber abrasion; ASTM D1044 haze after abrasion with haze to ASTM D1003 | Pencil hardness gives a quick floor check, typically 2H to 4H for a UV hard coat, and is operator sensitive, so one person runs it. Taber to ASTM D4060, with the wheel, load and cycle count stated, is reported as mass loss or wear index. On a transparent coating or a coated plastic, report abrasion as haze increase to ASTM D1044 with haze measured to ASTM D1003, stating the wheel, load and cycle count, typically CS-10F wheels, 500 g per wheel and 100 cycles. |
| Wetting tension and contact angle | ASTM D2578 (polyethylene and polypropylene film); ASTM D7334 contact angle | Test inks or dyne pens applied to the part about to be coated, not to a retained sample, with the system stated because pens and inks do not read alike. ASTM D2578 covers polyethylene and polypropylene film only, so on rigid mouldings and on metal it is quoted as the ink method and not as a conforming test; where a number has to go into a specification, use advancing contact angle to ASTM D7334. On glass and metal the water break test is the working check. |
| Dew point and substrate temperature | ISO 8502-4 | Hall temperature, relative humidity and substrate surface temperature read at the line, with the dew point taken from the tables or the instrument. The rule is substrate at least 3 C above dew point at application and until the film is through the flash zone. A cold part from winter stores can sit below dew point at a hall RH of 55 %, so the reading is taken on the part, not on the air. |
| Soluble salts and steel preparation | ISO 8502-6 Bresle patch with ISO 8502-9 conductivity; ISO 8501-1 blast grades; ISO 8503 profile | The Bresle patch extracts salt from a known area and conductivity converts it to a surface level, at least three patches per batch with one on a weld or a corner. Blast grade is judged against the ISO 8501-1 pictorial standards, typically Sa 2.5 for an industrial build, and profile is measured with a comparator or replica tape to ISO 8503 and recorded per batch. All three are taken on the prepared surface before coating, because none of them can be recovered afterwards. |
| Neutral salt spray | ASTM B117 or ISO 9227 NSS, rated to ASTM D1654 and ASTM D714 or ISO 4628-2 | Continuous salt fog on a scribed coated panel. B117 and ISO 9227 define how the cabinet is run and contain no rating scheme, so the exposure is rated separately: creep from the scribe to ASTM D1654, blistering to ASTM D714 or ISO 4628-2, rusting to ISO 4628-3, and the result reported as hours to the agreed rating. A comparative screen between systems, not a prediction of service life. On metal it tests the pre-treatment and the coating together, so the customer's own conversion coating and their own metal are used. |
| Oven cure profile | No single test standard; instrument method, recorded in house | A multi-channel data logger travels with the part, thermocouples attached to the heaviest section, the lightest section and a shadowed face. Report the ramp, the peak metal temperature and the minutes above the stated temperature for each channel, against the grade's schedule. Air temperature in the tunnel and the controller set point are not the cure; the metal temperature is. Re-profile after any change to loading, line speed, burner or extraction, and at least twice a year. |
| UV dose and peak irradiance | No single test standard; band matched radiometer, instrument and head band recorded | A radiometer carried through at running speed on a fixture that puts the head where the worst part face sits, reporting dose in mJ/cm2 and peak irradiance in W/cm2. Match the head band to the source: UV-A for a mercury arc or a 385 nm array, UV-V at roughly 395 to 445 nm for 395 and 405 nm arrays, since the UV-A band ends at 400 nm. Record the make, model, head band, calibration date, running speed and where on the part the head was fixtured, or the trace cannot be compared with the next one. |
Test methods
| Measurement | Method | What it tells you, and the usual acceptance |
|---|---|---|
| Concrete moisture and alkalinity | ASTM D4263 plastic sheet; ASTM F2170 in-situ relative humidity; ASTM F1869 calcium chloride | The sheet test is a go or no-go screen taped to the slab overnight. The in-situ probes give the number to work from, with holes numbered and placed per the standard for the floor area and each probe left to equilibrate in the slab for 24 h before it is read. The acceptance limit is set by the coating system and written into the specification with the grade: 75 % RH is a conservative default carried over from flooring adhesives, and many 2K epoxy systems are qualified to 80 or 85 % RH. F1869 may be used alongside where the specification calls for it, but it measures only the top 12 to 20 mm. Surface pH is checked alongside with pH paper and distilled water. |
When the press-floor fixes have not worked