Troubleshooting guide

UV Flexo Inks

Fault finding for the UniCure narrow-web UV flexo range: anilox, chambered blade, plate, mercury and LED cure.

Uniform Industries · Greater Noida, India · ufindustries.com
Figures are typical for the class and carry their test method. The values that govern a supply are those on the Technical Data Sheet for the grade.

Before you start

How to use this guide

Work down the page. Cheap checks before expensive ones, and measure before you change anything.

  • Safety before any check in this guide. Uncured UV ink and varnish are skin sensitisers and the sensitisation is irreversible, so nitrile gloves and eye protection whenever ink, chamber, blade or anilox is handled, and skin is washed with soap and water, never with solvent. MEK and wash-up solvents are flammable and harmful: small quantities only, at a ventilated bench away from lamps and ignition sources, contaminated cloths into a closed metal bin.
  • Every check that touches a blade, a cylinder, an anilox, a chamber, a lamp housing or an LED window is done with the press isolated and locked off and with lamps and arrays switched off and cooled. Used doctor blades go into a sharps container, never into a waste sack.
  • Never look at an operating mercury lamp or LED array, and wear UV eye protection where a shutter can open. Mercury lamps generate ozone: the extraction must be running and proved before a lamp is struck, and it is never turned down to chase a print fault.
  • Read the radiometer before you touch the ink. A UV flexo fault is a cure fault until a band-matched reading taken through the press at running speed says otherwise.
  • Measure surface energy on the reel you are about to run, not on the certificate that came with it; corona decays in storage and the ink cannot fix a 34 mN/m film.
  • Change one thing, run 200 metres, and read it. Anilox, blade, impression and lamp all move the same symptom, so two changes at once tells you nothing.
  • Adhesion, migration, bond strength and seal performance belong to the pack, not to the ink, so they are read on the customer's own construction after 24 h at 23 C and 50 % RH, never at the delivery.
  • Opaque white and dense black set the lamp requirement for the whole job, because they absorb and scatter the light the layers under them need.
  • If the ink has been in a warm chamber under stray light, treat it as suspect and replace it rather than trying to run it thinner.
UV Flexo InksHow to use this guide

01

The process

What happens, in order, and the one variable held at each step.

The process

What is controlled at each step

1Substrateand in-lineIn-line coronabrings PE, PP andPET-G up beforethe first deck;check the reel,not the label.Flame is aHOLDSurface energy 40to 44 mN/m2InkconditioningInk brought topress temperature,stirred, screenedinto the chamber;no stray UV on theline.HOLDInk temperature 18to 28 C3Aniloxmetering,Cell volume setsfilm weight; theblade wipes theland, it does notscrape the cells.HOLDAnilox volume, BCMor cm3/m24Plate tosubstratePhotopolymer ornatural rubber,kiss impressiononly; pressure isnot a densitycontrol.HOLDKiss impressionsetting5Interstationcure orEach colour isfixed enough tocarry the nextwithout trappingproblems orintercoat failure.On low-migrationHOLDInterstation dose,mJ/cm26Overprintvarnish andThe matchedUniCure OPV setsgloss, slip, ruband productresistance;specify it withthe ink.HOLDDelivered dose atthe substrate
UV Flexo InksThe process

Control variables

What to hold, and how to measure it

VariableTargetHow it is measuredHow it drifts
Delivered UV dose at the substrate80 to 150 mJ/cm2 UV-A for process colours, 120 to 200 for dense black, 150 to 250 for opaque white, metallics and low-migration sets. Typical for this class; each grade carries its own minimum on its data sheet.Band-matched radiometer carried through the press at running speed, read on the heaviest solid. At mercury stations use a four-band head and log UV-C as well as UV-A, because a lamp that has lost short-wave shows as a falling UV-C to UV-A ratio against the commissioning trace while the UV-A figure still looks acceptable. At LED stations a UV-A head is the correct instrument.Falls quietly. Lamp output decays with hours, quartz devitrifies and reflectors tarnish, so a console set at the same percentage delivers less every week. Nothing looks different until the first tack or adhesion complaint.
Peak irradiance at the web1 to 2 W/cm2 UV-A at the substrate under a focused 120 to 160 W/cm medium-pressure mercury lamp at the commissioning distance; a lower-rated or unfocused flood station sits below that in normal health, so judge it against its own commissioning trace rather than against an absolute floor. 8 to 16 W/cm2 at the emitting window for a 395 nm LED, held at the array manufacturer's working distance.Same radiometer pass; peak is read separately from dose, not calculated from it.Drops the moment lamp to substrate distance opens up after a web path change, a guard refit or a chill roller swap. Dose can still look right while peak has halved.
Substrate surface energy40 to 44 mN/m on corona-treated PE and PP. Below 38 mN/m, adhesion and resistance both fall away.Wetting tension test inks to ASTM D2578, applied to the reel about to run, read at two seconds, across the web and at both edges.Decays in storage over weeks and faster in a warm store. Slip and antiblock additives bloom to the surface and pull the reading down from the middle of the reel outwards.
Ink temperature in the chamber18 to 28 C at the chamber, measured at speed. This is not the storage range: unopened stock is stored at 15 to 25 C. Above 28 C the viscosity drop, the density climb and the dot gain that follows it start to move faster than the operator can correct; above 30 C treat the chamber as a standing gelling risk and fit cooling to the circulation.Probe thermometer in the chamber or return line, read at speed, not at standstill.Climbs through a run from pump shear, lamp infra-red and press-room heat. Viscosity falls as it climbs, so density rises and dot gain opens without anyone changing a setting.
Ink viscosity as supplied and in the chamberSeries typical at 25 C: process colours approximately 500 to 1200 mPa.s, opaque whites approximately 1200 to 2500 mPa.s, tube grades higher. UniCure Tube is pumpable at 800 to 2000 mPa.s and above on peristaltic pumps. UniCure IML is a low-viscosity grade formulated to release from very fine cells. Every figure is meaningless without the spindle, the speed and the temperature it was read at, because the ink is shear thinning.Rotational viscometry at 25 C with the spindle and speed fixed and recorded. A DIN 4 or ISO 2431 flow cup is a water-based and solvent-based tool and will not give a usable reading on a UV flexo ink.Moves with chamber temperature, not with time, because there is no solvent to evaporate. A reading taken cold in the morning and hot at midday can differ by a third.
Anilox cell volumeProcess on lamitube web 800 to 1200 lpi at 1.1 to 2.2 BCM (1.7 to 3.4 cm3/m2), spot 360 to 800 lpi, white 280 to 600 lpi. UniCure IML typically 1200 to 1500 lpi at 0.8 to 1.2 BCM, and to 1800 lpi at 0.5 to 0.8 BCM (0.8 to 1.2 cm3/m2) where the specification demands it. UniCure NX FD Opaque White at 120 l/cm and 10 to 12 cm3/m2, or at 180 l/cm and 7 to 9 cm3/m2. Pair every ruling with its own volume: volume falls as ruling rises, and a ruling quoted against the volume of a coarser roll cannot be engraved.Volume verified by the roll certificate at last audit, and cell condition checked with a 100x hand microscope on the running band. The trade uses two unit systems, so the conversions are: 1 BCM (billion cubic microns per square inch) equals 1.55 cm3/m2, and 1 line per cm equals 2.54 lines per inch. Quote ruling and volume in one system on the job sheet and put the other in brackets where the customer works in it.Falls as cells plug. A 10 % loss of volume is invisible to the eye and shows first as a density drop on the third or fourth colour, or as a white that has gone translucent.
Applied film weight1.2 to 2.0 g/m2 for narrow-web flexo process colours; 1.5 to 3.0 g/m2 for a UV overprint coating. Opaque white runs heavier and is the hardest layer to cure.Weigh a cut area of printed web against the same area of unprinted web on a four-place balance.Tracks anilox condition and blade pressure. Rises when the blade is backed off to hide a streak; falls as cells plug.
UV Flexo InksControl variables

Control variables

What to hold, and how to measure it

VariableTargetHow it is measuredHow it drifts
Doctor blade angle and contact pressureSet to the chamber manufacturer's geometry, with the lightest load that gives a clean wipe.Read blade load from the chamber's own pneumatic gauge in bar, or from its mechanical load scale, and record it on the job sheet. A feeler gauge sets blade protrusion from the holder; it does not measure contact pressure and must not be quoted as though it did. Use a straight-edge and a light to check the blade for wear and seating, with the press isolated.Operators add load through a shift to chase a streak. The blade then wears a wire edge, scores the anilox and the streak becomes permanent.
Web temperature under the lampsAs low as the chill rollers will hold it. Below 50 C on PE, below 55 C on PET-G shrink and below 70 C on PP, measured on the web after the last lamp.Infra-red thermometer or surface probe on the web immediately after the last lamp, and again at the rewind.Mercury lamps typically put 20 to 40 C of rise into the web at production speed, and 50 C or more at low speed or with no chill roller and no dichroic cold-mirror reflector. The rise climbs as the run goes on and as chill roller water warms. It is the limiting factor on thin PE, PP and shrink film and the usual reason such work moves to UniCure LED 395.
Stray light and heat on the ink lineNo daylight, no unshielded lamp and no hot surface anywhere on drums, pumps, hoses or the chamber.Walk the ink path with the press stopped and the room lights on; look for gaps in guards and reflected light off polished surfaces.Gets worse after maintenance, when a guard is left off or a lamp shield is refitted crooked. The ink gels in the pump or the chamber, usually overnight.
Web tension and colour to colour registerTension to the press setting sheet for the substrate and the reel diameter, held by a taper through the run. Register tolerance agreed with the customer; typical for this class is plus or minus 0.1 to 0.2 mm on filmic narrow web at production speed.Read the press tension display against the setting sheet at three reel diameters, and read register off the printed register marks with a linen tester or the press camera at the same three points. Record web temperature at the same time, because a warm web on thin PE or shrink film stretches and the register moves with it.Walks slowly as the reel diameter changes, as chill rollers drag and as the web warms. It is worst on thin PE and on shrink film, which stretch under tension that PET and paper would ignore.
Solid ink density and tone value increaseDensities and tone values to the approved print or the agreed characterisation, read every reel at the same points.Spectrodensitometer with the measurement conditions fixed and recorded: density status to ISO 5-3 (status E for European work, status T where the customer specifies it), 45/0 geometry to ISO 5-4, polarising filter stated as on or off, and the same white backing every time. Read tone value increase from the same control strip to ISO 12647-6.Rises with chamber temperature and impression, falls as anilox cells plug. Two operators reading without fixed conditions will disagree by more than the fault they are chasing.
UV Flexo InksControl variables

The mechanism

Why the surface is tacky and the bottom is hard

The film under the lampInk film 1.2 to 2.0 g/m2,about 1 to 2 micronTop micron: air interface,oxygen presentBody: oligomer, monomer,pigment, photoinitiatorBase: substrate interface,volumetric cure shrinkagetypically 5 to 10 %,roughly 2 to 3 % linear,At the surface: oxygenwinsOxygen quenches radicalsas fast as they form254 nm from mercury curesthis layer; LED has noneThin halftones suffermost: more surface pervolumeResult: hard underneath,thumb twist marks the topAt depth: pigment castsa shadowTitanium dioxide absorbsand scatters below 400 nm365 nm never reaches thebase of a heavy whiteGallium doping, 395 and405 nm get throughResult: soft base, pooradhesion, odour, migrationriskWhy slowing down doesnot fix itDose equals irradiancetimes time; the two halvesare not equalHalf the irradiance fortwice the time feedsoxygenRaise peak first: cleanoptics, close the distanceThen lengthen wavelengthfor depth, not shorten it

Cure is not one event through the thickness of the film. Oxygen attacks the top micron, pigment blocks the bottom, and the two faults call for opposite responses. Peak irradiance beats oxygen at the surface; longer wavelengths beat pigment at depth. Slowing the press does neither, which is why the instinctive fix so often makes the job worse.

UV Flexo InksThe mechanism

02  |  20 faults

Faults

Symptom, cause, check, change, confirm. The trap is the move to avoid.

Fault 1 of 20

Surface tacky, body of the film hard

WHAT YOU SEE

A thumb twisted on the solid leaves a mark and a smear, but a fingernail will not cut through to the substrate. It is usually worst on the light halftones and on the last colour down, and the reel blocks at the rewind.

WHAT IT LOOKS LIKE

FULL CURE5 mmTACKY SURFACE SKIN5 mmTwist a thumb on the solid: a full cure stays clean, an under-cured top layer smears.

    CAUSES, MOST LIKELY FIRST

  1. A lamp shuttered, failed or set below the job power, or line speed above the commissioned figureIt costs nothing to read the console and count the stations that are actually lit, and a web moving faster than the job was commissioned at takes dose out before anything else does. This is cleared in under a minute and is the commonest cause on a live press.
  2. Lamp to substrate distance opened up after a web path change, a guard refit or a chill roller swapIrradiance falls with distance much faster than dose does, so the console reading is unchanged while the cure is not.
  3. Peak irradiance too low at the webAtmospheric oxygen quenches free radicals at the air interface faster than a slow, weak exposure can generate them.
  4. Short-wave output lost from an aged lamp or a devitrified quartz sleeveThe 254 nm line cures the top micron and is the first thing a mercury lamp loses, while a broadband or UV-A-only radiometer still reads acceptably.
  5. Film too thin on the affected areaA light halftone has a high surface to volume ratio, so the oxygen-inhibited layer is a larger fraction of the total film.
UV Flexo InksSurface tacky, body of the film hard

Fault 1 of 20  ·  continued

Surface tacky, body of the film hard

CHECK, IN THIS ORDER

  • Read the console and count the lamps that are actually lit, and compare line speed with the commissioned figure, before fetching an instrument.
  • Pass a band-matched radiometer through the press at running speed and read dose and peak irradiance separately on the heaviest solid. At mercury stations use a four-band head and read UV-C as well as UV-A: a lamp that has lost short-wave shows as a falling UV-C to UV-A ratio against the commissioning trace while the UV-A figure still looks acceptable. At LED stations a UV-A head is the correct instrument.
  • MEK double rubs following the practice of ASTM D5402, using the house method recorded with the result: cloth type, a 1 kg load, the solvent, and one forward-and-back stroke counted as one double rub. Look for at least 30 with no breakthrough on the solid at the delivery. Gloves, eye protection and a ventilated bench.
  • With the press isolated and the lamps cooled, inspect quartz sleeves and reflectors for milkiness and film, and log lamp hours against the 1000 to 1500 h rating.
  • Measure lamp to substrate distance and compare it to the commissioning figure.

THEN CHANGE

  • Relight or reset the station to the job power, and return the line speed to the commissioned figure, before anything is changed on the ink.
  • With the press isolated and the lamps cold, clean quartz sleeves and reflectors, then remeasure. A filmed reflector loses more output than a tired bulb.
  • Restore peak irradiance next: close the lamp to substrate distance to commissioning, refocus or replace the reflector.
  • Replace the lamp when measured dose at the commissioning setting has fallen 25 to 30 %.
  • Correct the airflow pattern rather than the airflow volume: fit or repair the shrouding and air knives so the extraction draws from above the lamp housing and not across the web at the cure zone. Never reduce mercury lamp extraction to chase surface tack, because it is the ozone control and the lamp cooling.

CONFIRM IT IS FIXED

30 or more MEK double rubs by the house method following ASTM D5402, no breakthrough on the heaviest solid, no mark from a thumb twist at the delivery, and the radiometer dose and peak logged against the job number with the head type and the calibration date.

THE TRAP

Slowing the press. More time at the same low irradiance gives oxygen more time to quench the surface, so the tack often gets worse and the job now runs at half speed. Irradiance beats oxygen; dwell does not.
UV Flexo InksSurface tacky, body of the film hard (continued)

Fault 2 of 20

Print lifts on the tape test on treated film

WHAT YOU SEE

The print looks perfect at the delivery. A cross-cut and tape pull the next morning takes the ink off in flakes, or the die-cut waste matrix carries printed ink away with it.

WHAT IT LOOKS LIKE

SOUND ADHESION5 mmINK LIFTS ON TAPE5 mmRead the cross-cut lattice after tape pull: clean edges pass, squares lifting off the film fail.

    CAUSES, MOST LIKELY FIRST

  1. Surface energy on the reel has fallen below 38 mN/mCorona decays in storage, so a reel treated to 44 mN/m three months ago may be untreatable ink territory today.
  2. Slip and antiblock additives blooming to the film surfaceErucamide and similar migrate out of the polymer over weeks and form a low-energy layer the ink keys to instead of the film.
  3. Recycled-grade PE or PP in the printed faceMigrating additives carried in the recyclate reduce both adhesion and resistance; virgin grades are specified for printed faces.
  4. Under-cure leaving unreacted monomer at the interfaceVolumetric cure shrinkage of typically 5 to 10 %, roughly 2 to 3 % linear, generates stress at the interface, and a partly cross-linked film has no strength to carry it.
  5. In-line corona set for the last job, not this oneTreatment demand rises with line speed, so the watt density that held 42 mN/m at 80 m/min will not hold it at 150 m/min.
UV Flexo InksPrint lifts on the tape test on treated film

Fault 2 of 20  ·  continued

Print lifts on the tape test on treated film

CHECK, IN THIS ORDER

  • Wetting tension test inks to ASTM D2578 on the reel you are about to run, read at two seconds, at both edges and the centre, and again after in-line treatment.
  • Cross-cut to ISO 2409 with a tape pull, 24 h after cure at 23 C and 50 % RH. Use 2 mm cut spacing on flexible film, not 1 mm: ISO 2409 reserves 1 mm for thin coatings on hard substrates, and on film the finer lattice digs into the substrate and the classification stops meaning anything. Name the tape and its adhesion value on the report.
  • MEK double rubs following ASTM D5402 on the same sample, to separate an adhesion fault from an under-cure fault.
  • Check the reel certificate and the resin grade for recycled content in the printed face.
  • Calculate corona watt density, treater watts divided by web width times line speed, and compare it with the setting sheet at the speed the job runs.

THEN CHANGE

  • Raise in-line corona to hold 40 to 44 mN/m at the running speed, and re-measure at speed rather than on a stopped web.
  • Bring the cure up to the grade minimum before changing anything else about the ink.
  • Reject reels that will not treat, and specify virgin-grade film for printed faces.
  • On difficult laminates and tube web, pre-test on the customer's own material before production and prove it on a full construction.
  • Where the construction allows it, add the matched UniCure overprint varnish, which puts a continuous, more resistant layer over the print.

CONFIRM IT IS FIXED

ISO 2409 cross-cut classification at the cut spacing the standard gives for a flexible substrate, agreed with the customer on their own material, read 24 h after cure, plus MEK rubs at or above the grade minimum. Where a 1 to 2 micron ink over film cuts through and will not classify, agree a straight tape pull or a snap test on the customer's construction instead of forcing a class. Adhesion is a property of the interface and is qualified on the customer's construction, not claimed for the ink.

THE TRAP

Adding an adhesion promoter or a harder OPV to a film whose surface energy is 34 mN/m. It masks the fault for a day, the reel passes, and the labels fail at the customer three weeks later when the additive bloom has finished.
UV Flexo InksPrint lifts on the tape test on treated film (continued)

Fault 3 of 20

Density falls away through the run

WHAT YOU SEE

The first thousand metres are on colour. By the third reel the operator has closed the impression and opened the ink, and the solid is still light. A cotton bud on the anilox comes back barely marked.

WHAT IT LOOKS LIKE

ON DENSITY5 mmDENSITY FALLING AWAY5 mmCompare the solid with the start-up reel: watch for a weak, pale film as the anilox empties.

    CAUSES, MOST LIKELY FIRST

  1. Anilox cells plugging with cured or part-cured inkA UV ink does not dry, but stray light, heat and pigment settling leave a hard residue in the cell base that no amount of chamber pressure will lift.
  2. Dried-in wash-up solvent residue and paper lint in the cellsThe residue builds a floor in the cell, cutting effective volume long before the roll looks dirty.
  3. Ink temperature climbing and the operator compensating the wrong wayWarmer ink transfers differently, so a correction made hot is wrong when the press cools, and the roll ends up run harder than it needs.
  4. Blade load raised to chase a streakExcess load wipes the cell mouth as well as the land and reduces the volume actually released.
  5. Anilox volume already worn or previously scoredA roll that has been run with a worn blade has a polished band that carries less ink than its certificate says.
UV Flexo InksDensity falls away through the run

Fault 3 of 20  ·  continued

Density falls away through the run

CHECK, IN THIS ORDER

  • Look at the running band with a 100x hand microscope; compare a plugged area with the unused edge of the same roll.
  • Read ink temperature at the chamber at running speed, not at standstill.
  • Check the blade for a wire edge and the chamber seals for hardening, with the press isolated and gloves on.
  • Compare density with a spectrodensitometer against the approved print at the same points, every reel, with the measurement conditions fixed and recorded: density status to ISO 5-3, status E for European work or status T where the customer specifies it, 45/0 geometry to ISO 5-4, polarising filter stated on or off, and the same white backing every time. Read tone value increase from the same strip to ISO 12647-6.
  • Pull the anilox and have the volume audited if the roll has no recent certificate.

THEN CHANGE

  • Deep-clean the anilox off press, ultrasonically or by an approved chemical or bicarbonate process, and re-audit the volume.
  • Return blade load to the lightest clean wipe and reset impression to a kiss.
  • Hold chamber temperature in the 18 to 28 C band, with cooling on the ink circulation if the press-room runs hot.
  • Clean the anilox every time the ink comes off it: at every job change and every wash-up, not only when the roll is swapped out. Log each clean against the roll, and send the roll for deep clean and volume audit on a fixed interval rather than waiting for a density complaint.
  • If audited volume has fallen, move the job to a roll with the specified volume rather than pressing harder.

CONFIRM IT IS FIXED

Density held within the agreed tolerance across three consecutive reels at the same impression and the same anilox setting, read at the recorded measurement conditions, with cell structure clean under 100x across the full running band.

THE TRAP

Increasing impression to get the density back. It gains a little density, then gains dot gain, halo and plate wear, and it hides the plugging until the roll needs replacing rather than cleaning.
UV Flexo InksDensity falls away through the run (continued)

Fault 4 of 20

Blade lines and streaks through the solids

WHAT YOU SEE

One or more fine lines running in the web direction, often in the same place on every colour that shares the chamber design. Tracking the blade sideways moves the line with it.

WHAT IT LOOKS LIKE

EVEN SOLID5 mmBLADE LINE STREAKS5 mmLook along the web direction for fine lines that repeat on every colour sharing the chamber.

    CAUSES, MOST LIKELY FIRST

  1. A nick or wire edge on the doctor bladeA damaged edge leaves a ridge of unwiped ink that prints as a continuous line.
  2. Debris trapped under the bladeCured ink skin, pigment agglomerate, paper lint or die-cut dust rides under the edge and holds it off the roll.
  3. Blade load too highExcess load flexes the blade and makes it chatter against the land, which both scores the roll and streaks the print.
  4. Chamber end seals worn or badly fittedInk escapes past the seal, drags back into the running band and starves or floods a narrow strip.
  5. Anilox already scored from earlier runningA score is a permanent channel of extra volume and prints as a line whatever the blade does.
UV Flexo InksBlade lines and streaks through the solids

Fault 4 of 20  ·  continued

Blade lines and streaks through the solids

CHECK, IN THIS ORDER

  • Track the blade a few millimetres laterally with the press running, where the chamber allows it. If the line moves with the blade it is a blade fault; if it stays it is the roll. This settles the question in seconds and before anything is dismantled.
  • With the press isolated and wearing cut-resistant gloves, remove the blade and inspect the edge against a light, drawing a cotton bud across the edge. Never run a finger or a fingernail along a used blade: the wire edge is effectively a razor. Used blades go into a sharps container.
  • Strain the returning ink through a fine mesh and look at what the mesh catches.
  • Check blade load against the chamber gauge or load scale, and the blade angle against the manufacturer's geometry.
  • Inspect the end seals for hardening and compression set, and look at the anilox under 100x with the roll off press; a score will be visible as a bright line.

THEN CHANGE

  • Fit a new blade, set it to the manufacturer's angle and the lightest load that wipes clean.
  • Flush the chamber and filter the ink return; fit or renew an in-line filter if there is not one.
  • Renew the end seals as a pair, not one side.
  • If the anilox is scored, change the roll. A score does not polish out with load.
  • Where the same line returns on every job, have the roll audited rather than changing blades repeatedly.

CONFIRM IT IS FIXED

A clean solid across the full web width on 200 m of running, at the reset blade load, with the strainer clean at the end of that length.

THE TRAP

Winding blade load up to squeeze the streak out. It works for a minute, then wears the blade edge, scores the anilox and turns a two-minute blade change into a roll replacement.
UV Flexo InksBlade lines and streaks through the solids (continued)

Fault 5 of 20

Halftones plug and reverse text fills in

WHAT YOU SEE

Shadow dots have joined into solid, the reverse text has closed up and the vignette has a hard step in it. The plate looks wet and over-inked when the press stops.

WHAT IT LOOKS LIKE

OPEN SHADOW DOTS5 mmSHADOWS PLUGGED SOLID5 mmCheck the shadow dots and the reverse text: look for dots merged and counters closed up.

    CAUSES, MOST LIKELY FIRST

  1. Impression set above kissFlexo transfers on contact; extra pressure squeezes the dot sideways and fills the plate shoulder.
  2. Anilox ruling too coarse for the screen rulingThe cell must be smaller than the dot it feeds, or the dot picks up a bead of ink from several cells and prints larger than it is.
  3. Ink too thin at the chamber because the ink has warmedLower viscosity releases more freely from the cell and spreads further on contact.
  4. Plate relief or shoulder angle wrong for the rulingA shallow relief lets ink bridge between dots in the shadows; the plate, not the ink, is setting the tone curve.
  5. Plate swollen by an aggressive wash-up solventA swollen photopolymer prints soft and gains. It will usually recover most of its dimensions once the solvent has fully evaporated, so it is the repeated washing with an unapproved solvent, not one incident, that does the permanent damage.
UV Flexo InksHalftones plug and reverse text fills in

Fault 5 of 20  ·  continued

Halftones plug and reverse text fills in

CHECK, IN THIS ORDER

  • Take an impression print and back off to the first point where the solid is complete, then look at the shadows.
  • Check the anilox ruling against the plate screen ruling: the roll should be at least 5 to 6 times the screen ruling, so a 150 lpi screen needs 800 lpi or finer and a 175 lpi screen needs 1000 lpi or finer. Below about 4 to 1 the dot picks up ink from several cells and prints larger than it is.
  • Read the chamber ink temperature and the viscosity at 25 C on the same spindle and speed each time.
  • Measure plate relief and check the plate for swelling against a new one from the same set. Dry a suspect plate off press and re-measure the relief before condemning it.
  • Print and read a control strip, comparing tone value increase to the approved profile at the recorded measurement conditions.

THEN CHANGE

  • Reset impression to a kiss on every deck, starting from zero contact.
  • Move to a finer, lower-volume anilox for the halftone decks. UniCure IML is formulated to release from very fine cells, typically 1200 to 1500 lpi at 0.8 to 1.2 BCM, which is where fine work belongs.
  • Bring chamber temperature back into the 18 to 28 C band.
  • Replate with the correct relief and screen for the job, and change the plate wash to one approved for the plate material.
  • Compensate the file to the measured press curve only after the mechanical causes are cleared.

CONFIRM IT IS FIXED

Control strip tone value increase back inside the agreed curve and the reverse text legible at the specified point size on 200 m at production speed.

THE TRAP

Curve-correcting the file to fix a mechanical gain. The plate now has a wrong tone curve baked into it, and the next press, or the same press correctly set, prints the job too light.
UV Flexo InksHalftones plug and reverse text fills in (continued)

Fault 6 of 20

Pinholes, fisheyes and crawling on film

WHAT YOU SEE

Small round holes in the solid where the ink has pulled back to a rim, or the ink beads up and will not lay flat. Usually on filmic stock and often only on part of the web.

WHAT IT LOOKS LIKE

CONTINUOUS FILM5 mmCRATERS AND CRAWLING5 mmLook for small round holes with the ink drawn back to a raised rim, often in patches on the web.

    CAUSES, MOST LIKELY FIRST

  1. Surface energy too low for the ink to wet the filmIf the film's surface energy is below the ink's surface tension, the ink minimises contact area and beads.
  2. Silicone contamination on the web or in the press-roomSilicone from release liner, aerosol lubricant or a hand cream creates spots of very low surface energy the ink cannot cover.
  3. Air entrained in the ink by the circulation pumpFine bubbles carried into the cell burst at the nip and leave a hole that a 100 % solids ink has no flow to close.
  4. Overtreated filmExcessive corona degrades the surface and creates low-molecular-weight oxidised material that behaves like a contaminant.
  5. Water or wash solvent left in the chamberAn immiscible droplet in a solvent-free ink prints as a discrete defect.
UV Flexo InksPinholes, fisheyes and crawling on film

Fault 6 of 20  ·  continued

Pinholes, fisheyes and crawling on film

CHECK, IN THIS ORDER

  • Test inks to ASTM D2578 across the web, looking for a low band rather than a low average.
  • Wipe a suspect area with isopropanol on a lint-free cloth, gloves on and away from ignition sources, and reprint that strip; a defect that disappears is contamination.
  • Look into the chamber at running speed for foam on the ink surface.
  • Check the treater against the film and speed by calculating watt density, treater watts divided by web width times line speed, and comparing it with the setting sheet. Confirm overtreatment by testing the unprinted back of the web with test inks, because backside treatment is the reliable marker. Do not use smell: if ozone can be smelled at the treater the extraction has failed, which is a stop-and-repair condition, not a measurement.
  • Inspect idler rollers and the web path for silicone transfer from liner or lubricant.

THEN CHANGE

  • Bring in-line treatment to 40 to 44 mN/m and no higher.
  • Ban silicone sprays from the press-room and clean the web path and idlers with isopropanol.
  • Reduce pump speed, keep the chamber return below the ink surface so it does not whip air in, and let the ink stand to de-aerate.
  • Strain the ink and flush the chamber and lines after a wash-up, then prime with fresh ink.
  • Reject a reel that shows contamination across its width rather than trying to print through it.

CONFIRM IT IS FIXED

A continuous solid with no holes over 200 m at production speed, with test inks reading 40 to 44 mN/m across the full width immediately before the first deck.

THE TRAP

Adding a slip or flow additive to make the ink wet a contaminated film. It lowers the ink's surface tension enough to cover the defect, and it also lowers rub resistance, spoils the key for the overprint varnish and makes the whole reel block.
UV Flexo InksPinholes, fisheyes and crawling on film (continued)

Fault 7 of 20

Opaque white is not opaque enough

WHAT YOU SEE

On clear film the white looks grey or translucent against the light box, the printed colours over it shift towards the pack contents, and adding more white makes the curing worse rather than the opacity better.

WHAT IT LOOKS LIKE

FULL OPACITY5 mmTRANSLUCENT WHITE5 mmHold the print to the light box: a sound white hides the background, a thin white reads grey.

    CAUSES, MOST LIKELY FIRST

  1. Anilox volume too low for the whiteOpacity is film weight; a white laid at process-colour volume simply does not contain enough titanium dioxide per square metre.
  2. Under-cure at the base of the white filmTitanium dioxide absorbs and scatters below about 400 nm, so the bottom of a heavy white starves of light and stays soft, which then limits how much can be laid.
  3. A single hit where the job needs twoTwo thinner, fully cured hits give more opacity than one heavy hit that cannot cure through.
  4. Wrong white for the jobA transparent or tint white is formulated for shading, not for covering; the first-down opaque grade is a different product.
  5. Lamp spectrum wrong for a pigmented whiteA 365 nm-weighted source is absorbed at the top of the film; the energy that reaches depth comes from 395 to 420 nm.
UV Flexo InksOpaque white is not opaque enough

Fault 7 of 20  ·  continued

Opaque white is not opaque enough

CHECK, IN THIS ORDER

  • Confirm the anilox ruling and its own volume as a pair: UniCure NX FD Opaque White at 120 l/cm and 10 to 12 cm3/m2, or at 180 l/cm and 7 to 9 cm3/m2. A fine ruling quoted against a coarse roll's volume cannot be engraved, so a roll ordered that way arrives as a compromise and the white is blamed for it.
  • Weigh the applied white by differential weighing of printed against unprinted web.
  • Radiometer pass at running speed, UV-A band, read on the white itself rather than on a process solid.
  • Cross-cut and MEK rub the white alone before any colour goes over it.
  • Measure opacity on a light box against the approved sample, or with a contrast-ratio reading over black and white backing.

THEN CHANGE

  • Move to the specified white ruling and its matching volume before changing anything in the ink.
  • Raise the dose on the white deck towards 150 to 250 mJ/cm2 UV-A and check peak irradiance as well as dose.
  • Change to a gallium-doped mercury lamp, or run the white station at 395 or 405 nm, to get light past the titanium dioxide absorption edge.
  • Print two hits of white with a cure between them rather than one heavy hit. This is also the answer where the opacity target would otherwise need a fine ruling and a coarse roll's volume at the same time.
  • Confirm the grade is the first-down opaque white, NXW-1000, and not a transparent or tint white.

CONFIRM IT IS FIXED

Opacity matched to the approved sample on the customer's own clear film, with the white passing MEK rubs and cross-cut on its own before overprinting.

THE TRAP

Reaching for a shorter wavelength or more of the same lamp on a heavy white. Short-wave energy never gets to the bottom of a titanium dioxide film; white work is moved to longer wavelengths, not given more of a shorter one.
UV Flexo InksOpaque white is not opaque enough (continued)

Fault 8 of 20

Ink gels in the chamber, pump or drum

WHAT YOU SEE

The ink has turned to jelly or rubber, usually overnight or over a weekend. Sometimes only the pump head or a length of hose is solid while the drum is still liquid.

WHAT IT LOOKS LIKE

INK STILL FLUID5 mmGELLED IN THE CHAMBER5 mmCheck chamber, pump head and hose for ink turned to jelly while the drum is still liquid.

    CAUSES, MOST LIKELY FIRST

  1. Stray light on the ink lineA UV ink cures by reaction, not by drying, so daylight, an unshielded lamp or a reflection off polished metal is enough to start radicals in a static line.
  2. Heat in the chamber or pumpThermal initiation and shear heating both start the same polymerisation; the inhibitor package is consumed and the ink kicks.
  3. Oxygen starved out of a sealed or completely full ink systemThe hydroquinone-type inhibitors in a UV ink only work in the presence of dissolved oxygen. A line with no headspace, an airless or nitrogen-blanketed system, or a drum decanted and sealed full can gel in the dark at ambient temperature, which is why these events survive every light and heat check on the list.
  4. Contamination with a curing agent, peroxide or amine from another productA trace of an incompatible chemistry from a shared pump or a mis-labelled container will kick a whole drum.
  5. Old stock past the six-month shelf life, or stored above 25 CThe stabiliser package depletes over time and faster when warm.
UV Flexo InksInk gels in the chamber, pump or drum

Fault 8 of 20  ·  continued

Ink gels in the chamber, pump or drum

CHECK, IN THIS ORDER

  • Walk the ink path with the press stopped and room lights on, looking for gaps in guards and reflected light.
  • Feel and measure the pump body, hoses and chamber temperature at the end of a run.
  • Check whether any part of the circulation is sealed or run full with no air contact, and whether any container has been decanted and sealed to the brim or blanketed with nitrogen.
  • Check the batch number and date against the 6-month shelf life on the 5 kg pack, and check whether the pump, hose or chamber has been used for another chemistry.
  • Check the store: 15 to 25 C, closed original containers, out of direct light.

THEN CHANGE

  • Shield the ink line completely; guard lamps and fit opaque hose and covers.
  • Empty and clean the chamber, pump and lines at the end of the shift; do not leave ink standing in a warm press or in a dead leg of the circulation.
  • Leave an air headspace in stored and part-used containers, and do not blanket UV ink with nitrogen or run it in a sealed airless loop. Keep the chamber return below the ink surface so it does not whip air in: the ink needs air contact, not agitation, and a chamber that foams gives pinholes, blade skip and lost density.
  • Dedicate pumps and hoses to UV, and never share with a two-pack or peroxide-cured product.
  • Scrap gelled ink. It is irreversible, and thinning or straining it will not recover it. Treat a warm or gelling container as an exothermic reaction in progress: do not seal it, move it to a designated safe area away from heat and combustibles, keep it under observation until it is cold, and dispose of it as hazardous waste to the safety data sheet. Never return suspect ink to a bulk drum.

CONFIRM IT IS FIXED

Clean ink at the chamber after a full weekend standstill with the line filled, and no rise in viscosity at 25 C from the reading logged at fill, taken on the same spindle and speed.

THE TRAP

Stirring a part-gelled ink back in and running it. The gel particles print as hard specks, block the finest cells on the anilox, and the rest of the drum kicks solid within the shift.
UV Flexo InksInk gels in the chamber, pump or drum (continued)

Fault 9 of 20

Overprint varnish or foil will not key to the print

WHAT YOU SEE

The OPV crawls or lifts over the solids, or a hot-foil block will not take, or a second UV layer peels cleanly away from the first at the tape test.

WHAT IT LOOKS LIKE

VARNISH KEYED DOWN5 mmVARNISH PEELS OFF PRINT5 mmTape pull the varnish over the solids: a keyed layer stays, a poor key peels away cleanly.

    CAUSES, MOST LIKELY FIRST

  1. The underlying ink is over-curedA fully cross-linked, hard surface has no residual unsaturation for the next layer to react into, so the bond has to be purely physical.
  2. Slip additive or wax at the surface of the ink filmThe same additive that gives low friction lowers surface energy and stops the next layer wetting and keying.
  3. Wrong overprint varnish for the jobThe range is specified by function: CSC 84RC accepts hot-foil stamping and glueing, ASC 88RC is the anti-static grade for IML, and the TLC series carries both a thermal grade that preserves thermal print-head compatibility and a flexible grade for lamitube web. Those two TLC codes differ by two digits, so take the code from the current coatings list and check it against the drum label before ordering. A general gloss will not do any of these jobs.
  4. Too long between print and coatCross-linking continues for hours after the lamp, so an off-line coating pass onto a day-old reel keys far less well than an in-line one.
  5. Contamination picked up on the rewindSilicone from a liner, or dust, sits between the two layers.
UV Flexo InksOverprint varnish or foil will not key to the print

Fault 9 of 20  ·  continued

Overprint varnish or foil will not key to the print

CHECK, IN THIS ORDER

  • Cross-cut to ISO 2409 with a tape pull on the coated sample after 24 h at 23 C and 50 % RH, at the cut spacing the standard gives for the substrate, and with the tape named on the report.
  • Measure interstation dose on the deck below; over-cure here is as real a fault as under-cure.
  • Confirm the OPV grade against the end use from the matched coating list, and confirm the code on the drum label.
  • Check the elapsed time and storage between the print pass and the coating pass.
  • Test wetting of the OPV on the printed solid with test inks or by a simple draw-down.

THEN CHANGE

  • Reduce the interstation dose on the deck below to pin rather than cure out, typically 20 to 50 mJ/cm2 UV-A, which sets the film but leaves residual surface unsaturation, and give the full dose after the varnish.
  • Do not apply that pinning fix on UniCure FP low-migration work. On low-migration constructions every layer is cured to the grade minimum, because residual monomer and photoinitiator fragments are the migration and odour route, and keying is solved instead with the matched low-migration coating, in-line coating and inter-deck corona.
  • Move to the correct matched UniCure OPV for the end use rather than the general-purpose gloss.
  • Coat in line where the press allows it, and within the same shift where it does not.
  • Where slip is being carried by the ink, move the slip into the OPV, for example HSC 81RC where labels must slide through downstream handling.

CONFIRM IT IS FIXED

ISO 2409 cross-cut with tape on the finished construction after 24 h, agreed with the customer, plus a foil pull or a glue test where the job needs one.

THE TRAP

Dosing the lower deck harder because the top layer is failing. It looks like the fix for an adhesion problem, and here it is the cause: the harder the layer below is cured, the less the layer above can key into it.
UV Flexo InksOverprint varnish or foil will not key to the print (continued)

Fault 10 of 20

Reel blocks, print transfers to the back

WHAT YOU SEE

The reel will not unwind cleanly, the label face has picked up a ghost of the print, or the liner has taken ink off the face. Worst in the core of the reel and in warm weather.

WHAT IT LOOKS LIKE

CLEAN UNWIND5 mmPRINT SET OFF IN REEL5 mmUnwind from the core and look at the reverse for a ghost of the print picked off the face.

    CAUSES, MOST LIKELY FIRST

  1. Surface under-cure carried into the reelA tacky film under pressure for hours will weld to whatever is against it; the reel is a press with a very long dwell.
  2. Rewind tension too highPressure at the core multiplies through the reel and forces the layers into intimate contact.
  3. Web still warm at the rewindA mercury station typically puts 20 to 40 C of rise into the web at production speed, and more at low speed or with no chill roller, and a hot reel blocks where a cool one would not.
  4. No overprint varnish where the construction needs oneThe matched OPV carries the slip and scuff resistance; an uncoated ink surface has neither.
  5. Heavy film weight on the last colour downThe heaviest, last-cured layer is the one most likely to be tacky and the one in contact with the back of the web.
UV Flexo InksReel blocks, print transfers to the back

Fault 10 of 20  ·  continued

Reel blocks, print transfers to the back

CHECK, IN THIS ORDER

  • Thumb twist and MEK double rubs following ASTM D5402 at the delivery on the last colour down.
  • Measure web temperature at the rewind with an infra-red thermometer, and again after the last lamp.
  • Check rewind tension and taper against the setting sheet.
  • Check chill roller water temperature and flow.
  • Measure static and dynamic coefficient of friction to ASTM D1894 on the finished face against the reel backing.

THEN CHANGE

  • Fix the cure first: raise peak irradiance and clean the optics, and confirm 30 or more MEK double rubs.
  • Fit or repair chill rollers, and fit dichroic cold-mirror reflectors where the substrate is heat-sensitive.
  • Reduce rewind tension and set a taper so the core is not the tightest part of the reel.
  • Apply the matched UniCure OPV, for example SRC 89RC where the highest scratch and scuff resistance is needed or HSC 81RC where a very low coefficient of friction is wanted.
  • Let reels cool to ambient before stacking or shipping, and do not stack a warm reel on its side.

CONFIRM IT IS FIXED

A blocking test at a stated pressure and climate: printed face against the reel back, 24 h at 40 C and 50 % RH under a load of about 10 kPa, with no ink transfer and no change in the printed image on separation. Confirm on a full reel wound at production speed at the set tension and taper, and use the customer's own blocking method and load where they have one.

THE TRAP

Winding the reel harder so it looks tidy on the pallet. It is the tension that welds a slightly tacky film, so a neat reel at high tension blocks where a soft reel would have survived.
UV Flexo InksReel blocks, print transfers to the back (continued)

Fault 11 of 20

Job moved to LED will not cure

WHAT YOU SEE

The ink ran perfectly under mercury. On the LED deck the solids are soft, the whites are worst, and turning the array to 100 % changes almost nothing.

WHAT IT LOOKS LIKE

CURED UNDER LED5 mmSOFT WHITES ON LED5 mmRub and twist the whites first: under LED an unmatched initiator leaves a soft, marking surface.

    CAUSES, MOST LIKELY FIRST

  1. A mercury-cure ink on an LED arrayA conventional UV ink relies on photoinitiators absorbing below 380 nm; a 395 nm array emits nothing there, so the ink may not cure at all. The LED job needs the LED-cure grade, UniCure LED 395.
  2. Dose read with a broadband radiometer headA broadband head will not report what a 385 to 405 nm array delivers, so the reading that says the dose is fine is simply the wrong instrument.
  3. Working distance wrong for the arrayLED peak irradiance falls very fast with distance; 8 to 16 W/cm2 at the emitting window is not what arrives 20 mm further away.
  4. Dirty or obscured emitting windowInk mist and dust on the quartz window cut output directly, and LED arrays give no visual cue that they have lost power.
  5. No infra-red to help, on a job that was relying on itLED puts almost no heat into the web, so a film weight or substrate that was carried by a little thermal post-cure under mercury is now on its own.
UV Flexo InksJob moved to LED will not cure

Fault 11 of 20  ·  continued

Job moved to LED will not cure

CHECK, IN THIS ORDER

  • Confirm the ink grade is an LED-cure grade before anything else.
  • Radiometer pass with a UV-A band head at the LED station, at running speed, on the heaviest solid.
  • Measure the working distance from emitting window to web and compare it with the array manufacturer's figure.
  • With the press isolated and locked off and the array switched off, cooled and confirmed dark, clean the emitting window with the cloth and solvent the array manufacturer specifies, because many quartz and coated windows are damaged by ketones. Remeasure and record before and after. Never clean or inspect a window on a live array, and never judge from the absence of visible light whether an array is emitting.
  • MEK double rubs following ASTM D5402 on the heaviest solid at the delivery.

THEN CHANGE

  • Change to UniCure LED 395 for LED decks. It is formulated for 395 nm LED cure and also cures under mercury, so it suits a hybrid press-room, and a 365 nm version is available on request. Speeds of up to approximately 150 m/min have been reached on process colours at 1.2 to 2.0 g/m2 under a single 16 W/cm2 395 nm array at the specified working distance; opaque white, dense black and heavier lays need more. That is a formulation capability, not a guaranteed line speed, and the achievable speed is established on the customer's press and substrate.
  • Fit the correct UV-A band head and recalibrate the radiometer to that band.
  • Set the working distance to the array specification and hold it with the guard fitted.
  • Clean the emitting window on a shift schedule, with the station isolated and cold.
  • Move opaque white to the 395 or 405 nm emitters rather than to a shorter wavelength.

CONFIRM IT IS FIXED

30 or more MEK double rubs following ASTM D5402 at the target line speed, with UV-A dose and peak irradiance logged from a band-matched head at the LED station, on the colour and film weight the job actually runs.

THE TRAP

Turning the array to full and running slower to force a mercury ink to cure. It burns array life, heats the film enough to distort it, and still leaves unreacted monomer because the ink's photoinitiator has nothing to absorb at 395 nm.
UV Flexo InksJob moved to LED will not cure (continued)

Fault 12 of 20

Odour or taint reported on low-migration work

WHAT YOU SEE

The converter or the brand owner reports a smell in the finished pack, or a sensory panel picks up taint. The print itself looks and rubs fine.

WHAT IT LOOKS LIKE

NO ODOUR CARRIED5 mmTAINT IN THE PACK5 mmNothing shows on the print: smell the reel and the made-up pack, and run the sensory panel.

    CAUSES, MOST LIKELY FIRST

  1. Incomplete cure leaving residual monomer and photoinitiator fragmentsUnreacted material stays mobile in the film and comes off as odour; low odour and full resistance both follow from complete cure, not from the ink alone.
  2. Film weight above what the lamp can cure throughThe base of a heavy layer is the last to cure and the first to leave residuals.
  3. A non-low-migration ink or varnish used somewhere in the constructionOne conventional overprint varnish over a low-migration ink puts the whole pack back where it started.
  4. Interstation decks pinned rather than cured outPinning is a keying technique for general label work. On low-migration work it leaves exactly the mobile material the construction exists to avoid.
  5. Set-off from the reverse of the web in the reel, or solvent and cleaner residue in the pressUncured material transfers to the unprinted side and travels to the food-contact face, and wash-up solvent trapped in a chamber or on a roller is often the real source of what is reported as ink odour.
UV Flexo InksOdour or taint reported on low-migration work

Fault 12 of 20  ·  continued

Odour or taint reported on low-migration work

CHECK, IN THIS ORDER

  • Radiometer pass on the heaviest solid and compare with the 150 to 250 mJ/cm2 UV-A band that low-migration sets normally need.
  • MEK double rubs following ASTM D5402 on every colour, not just the one that looks worst.
  • Check the interstation settings deck by deck and confirm every layer is cured out, not pinned.
  • Audit the full construction: every ink, primer, varnish and adhesive, by grade code.
  • Run a sensory check to DIN 10955, the closed-jar Robinson test, on printed and converted material against unprinted substrate as the reference, with a trained panel, the storage time and temperature stated, and the result reported on the 0 to 4 scale. Where the brand owner has their own sensory method, run theirs and report against their acceptance. Check wash-up practice and what solvent was last through the chamber.

THEN CHANGE

  • Bring the dose up to the grade minimum and raise peak irradiance; confirm with a radiometer pass, not a console figure.
  • Reduce film weight to the minimum that gives the required density, and split heavy lays into two cured hits.
  • Cure every deck out on low-migration work and solve keying with the matched low-migration coating, in-line coating and inter-deck corona instead of pinning.
  • Use the matched low-migration coatings, LMC 83RC gloss or LMM 72RC matt, over UniCure FP, not a general-purpose varnish.
  • Keep the food-contact face free of print and keep set-off out of the reel with correct tension and a cool rewind, and change wash-up solvent and drying practice so nothing is left in the chamber or on the rollers.

CONFIRM IT IS FIXED

Sensory assessment to DIN 10955 or the customer's own method on the finished pack, agreed with the customer, plus MEK rubs at or above the grade minimum on every colour and the dose logged. UniCure FP is formulated using photoinitiators listed in the relevant groups of the current EuPIA suitability list for low-migration UV inks, with the list version and date stated on the data sheet, and raw materials selected under the EuPIA Exclusion Policy and Good Manufacturing Practice guidance. Conformity of the finished article is assessed on the customer's own converted pack against Regulation (EC) 1935/2004 and, where it applies, the Swiss Ordinance Annex 10 lists, by specific migration testing at an accredited laboratory on the actual construction, filling and storage conditions. It is not claimed from the ink, and a sensory pass is not a migration pass.

THE TRAP

Adding a low-odour varnish over the top to cover a smell. It seals unreacted monomer under a barrier for a few days, then the odour returns from the reel and the construction now has an extra uncured layer in it.
UV Flexo InksOdour or taint reported on low-migration work (continued)

Fault 13 of 20

Sleeve ink cracks or flakes in the tunnel

WHAT YOU SEE

The print survives the press and the seaming, then splits, whitens or flakes where the sleeve has drawn in most, usually at the shoulder or the waist of the container, or in a band either side of the seam.

WHAT IT LOOKS LIKE

FILM SHRINKS WITH SLEEVE5 mmINK SPLITS ON SHRINK5 mmLook at the shoulder and the waist after shrink for splits, whitening and flaking ink.

    CAUSES, MOST LIKELY FIRST

  1. Over-cure making the film too hard to follow the shrinkUniCure Shrink is formulated to follow the transverse shrink of PVC, OPS and PET-G sleeve film, up to approximately 75 % TD on PET-G and 78 % on the highest-shrink grades. A heavily over-dosed film is more cross-linked, more brittle and cracks before the film stops moving. This is listed first because it is the counter-intuitive one: the symptom reads as under-cure and the instinctive response makes it worse.
  2. Seaming solvent attacking the printSleeves are seamed with THF, dioxolane or a blend. Applied too heavily, applied wide, or run too slowly, it softens and partly redissolves the cured ink for several millimetres either side of the seam, and that band whitens and cracks as the sleeve draws. Rank this first where the defect is seam-located.
  3. Film weight too heavy on the area of greatest drawA thick film cannot elongate with a thin one under it; the strain concentrates at the surface and opens a crack.
  4. Wrong ink class for the filmA standard label ink has no elongation designed into it. PVC, PET-G and OPS take the shrink grade, and PP is limited for this chemistry.
  5. Tunnel profile too aggressive at the start, or treatment lost on the printed faceA steep early heat rise shocks the print before the film has begun to relax, so the ink takes the strain instead of the film; and without in-line corona on the printed face the ink has a weak key and lets go as soon as the film moves.
UV Flexo InksSleeve ink cracks or flakes in the tunnel

Fault 13 of 20  ·  continued

Sleeve ink cracks or flakes in the tunnel

CHECK, IN THIS ORDER

  • Compare a seam-area sample with a sample 50 mm away from the seam. A defect that stops a few millimetres from the seam is the seaming solvent, not the cure and not the film weight.
  • Radiometer pass and MEK rubs; look for over-cure as carefully as for under-cure on this class.
  • Weigh the film in the high-draw area and compare with the low-draw area.
  • Confirm the ink grade and the film type against the specification, and check whether PP is in the construction.
  • Map the tunnel with a travelling thermocouple or a profiling logger through a full pass, and test inks to ASTM D2578 on the in-line-treated printed face.

THEN CHANGE

  • Reduce dose to the grade minimum rather than the press maximum, and verify by MEK rubs, not by appearance.
  • Cut the seaming solvent volume and the application width, and check the dwell on the seaming machine, where the defect is seam-located.
  • Reduce film weight in the high-draw zone by moving to a lower-volume anilox on those decks.
  • Confirm UniCure Shrink is on all decks including the white; opaque white is available in standard and LD high-slip versions for reverse-printed sleeves.
  • Soften the entry of the tunnel profile so the film starts to relax before the print is fully heated, and bring in-line corona on the printed face to 40 to 44 mN/m.

CONFIRM IT IS FIXED

A full shrink trial on the customer's own film and container, at their tunnel profile and with their seaming solvent and settings, with no cracking, whitening or flaking at the maximum draw or either side of the seam, assessed after 24 h.

THE TRAP

Adding dose because the ink is flaking. Flaking reads like under-cure, and on shrink work it is more often the opposite: extra cross-linking makes the film stiffer and it cracks sooner.
UV Flexo InksSleeve ink cracks or flakes in the tunnel (continued)

Fault 14 of 20

IML labels double-pick or curl in the magazine

WHAT YOU SEE

The robot lifts two labels, or none, or the label will not sit flat in the mould. Sometimes the label fuses badly and shows washout lines from the injected resin.

WHAT IT LOOKS LIKE

LABEL LIES FLAT5 mmLABEL CURLING IN STACK5 mmStand a label on the bench: a flat label feeds singly, a curled one double-picks in the magazine.

    CAUSES, MOST LIKELY FIRST

  1. The moulding line itselfSingle-label pick is decided by the magazine setting and spring load, the vacuum cup condition and vacuum level, the die-cut edge and its burr, the static bars and the press-room humidity. IML runs single-pick every day on constructions with no anti-static coating, so the free mechanical causes are checked before anything is bought.
  2. Static on the printed faceCharge generated at the die-cut and in the magazine holds labels together, and a balanced static condition is what lets one label release.
  3. Coefficient of friction out of balance between the two facesIf the printed face and the reverse have similar friction, the labels behave as a block rather than releasing one at a time.
  4. Label curl from the film and the conditioning, not from the inkCure shrinkage of a 1 to 2 micron ink layer on a 50 to 80 micron film is about 2 to 3 % of the thickness and cannot on its own bow a label in the magazine. Curl on IML is dominated by the film's own orientation and heat set, by the temperature and flatness the cut labels were stacked and conditioned at, and, on paper-faced constructions, by moisture.
  5. Ink not keyed enough to take the injectionA partly cured film has no cohesive strength and washes out when the resin front passes over it.
UV Flexo InksIML labels double-pick or curl in the magazine

Fault 14 of 20  ·  continued

IML labels double-pick or curl in the magazine

CHECK, IN THIS ORDER

  • Check the moulding line first: magazine setting and spring load, vacuum cup condition and vacuum level, die-cut edge quality and burr.
  • Measure static with a field meter at the die-cut, at the stacker and in the magazine, and record press-room humidity.
  • Measure static and dynamic coefficient of friction to ASTM D1894 on both faces of the finished label.
  • Check the anilox against the specification and lay ten labels on a flat surface to measure the lift at the corners as a curl check; then check the film grade, the store conditions and how the cut labels were stacked.
  • MEK double rubs following ASTM D5402 and a short injection trial on the customer's tool.

THEN CHANGE

  • Correct the moulding line causes first: magazine, vacuum, die-cut edge, static bars at the die-cut and stacker, and press-room humidity.
  • Apply ASC 88RC anti-static, benzophenone-free overprint varnish where static at the magazine is the limiting factor on pick.
  • Reduce ink film weight to the specification as good practice, but look first at the film grade, the press-room and store humidity and the stacking and conditioning of the cut labels for curl.
  • Bring the cure to the grade minimum so the film has the cohesive strength to resist injection washout.
  • Condition cut labels flat, under light weight, before they go to the magazine.

CONFIRM IT IS FIXED

A production trial on the customer's moulding line with single-label pick on 200 consecutive cycles, no visible washout, and coefficient of friction to ASTM D1894 inside the agreed band on both faces. Single-label pick is qualified on the customer's moulding line and is not claimed from the coating.

THE TRAP

Adding slip to the ink to cure a picking problem. It cuts friction on both faces equally, so the labels still behave as a block, and it ruins the key for the anti-static varnish that would actually have helped.
UV Flexo InksIML labels double-pick or curl in the magazine (continued)

Fault 15 of 20

Lamitube print cracks at forming or after filling

WHAT YOU SEE

The printed web is fine flat. The crack appears at the seam, at the shoulder, or after the tube has been squeezed a few times in use, and it often looks like a fine crazing rather than a clean break.

WHAT IT LOOKS LIKE

FLEXES WITHOUT CRAZING5 mmCRAZING AT THE FOLD5 mmLoupe the seam and shoulder for fine crazing in the film after forming and after squeezing.

    CAUSES, MOST LIKELY FIRST

  1. Ink film too hard for a substrate that is formed after printingA lamitube is printed flat, then formed, seamed, filled and squeezed for the life of the tube, so the film has to stay flexible rather than reach maximum hardness.
  2. Wrong overprint varnishThe lamitube web takes the flexible, product-resistant grade from the TLC series, and UniCure 5500PE OPV is specified with these inks. The TLC thermal grade and the TLC lamitube grade differ by two digits, so take the code from the current coatings list and check it on the drum label. A rigid label gloss will craze.
  3. Film weight too heavy at the seamThe seam is the highest-strain area and a heavy film there has nowhere to go.
  4. Laminate construction not pre-testedEvery tube laminate behaves differently under the forming head, which is why every laminate is pre-tested before production.
  5. Product attack from inside the tubeOral care and ointment actives plasticise or swell an under-cured film over weeks, and the crazing appears at the customer, not at the plant.
UV Flexo InksLamitube print cracks at forming or after filling

Fault 15 of 20  ·  continued

Lamitube print cracks at forming or after filling

CHECK, IN THIS ORDER

  • Confirm anilox rulings against their own volumes: process 800 to 1200 lpi at 1.1 to 2.2 BCM, spot 360 to 800 lpi, white 280 to 600 lpi.
  • MEK rubs following ASTM D5402 and a mandrel or fold test on the printed flat web.
  • Check which overprint varnish is on the job, by code on the drum label, and against what specification.
  • Form and seam a short trial length on the customer's own laminate and head setting.
  • Fill a small number of tubes with the actual product and hold them at 40 C for four weeks, then squeeze and inspect.

THEN CHANGE

  • Confirm UniCure Tube grades throughout, which are pumpable at 800 to 2000 mPa.s and above on peristaltic pumps.
  • Apply UniCure 5500PE OPV or the TLC lamitube grade as the matched coating; the coating is not optional on this work.
  • Reduce film weight in the seam area by moving to a lower-volume anilox on the decks that print there.
  • Bring the cure to the grade minimum and no higher, and verify by rubs rather than by hardness.
  • Pre-test every laminate with the customer before production.

CONFIRM IT IS FIXED

A formed, seamed, filled and aged tube trial on the customer's own laminate and product, with no crazing or cracking at the seam or shoulder after four weeks at 40 C and repeated squeezing. Performance after forming and filling belongs to the construction and is qualified on the customer's material.

THE TRAP

Treating tube work like label work and pushing dose and hardness up for product resistance. Resistance on a tube comes from a fully cured but flexible film plus the matched coating, and a harder film simply cracks sooner at the seam.
UV Flexo InksLamitube print cracks at forming or after filling (continued)

Fault 16 of 20

Bars or bands across the web on solids

WHAT YOU SEE

Regular light and dark bands running across the web, often with a spacing that matches the plate or the anilox circumference. Worse at certain speeds and better at others.

WHAT IT LOOKS LIKE

FLAT EVEN SOLID5 mmBARS ACROSS THE WEB5 mmView the solid at arm's length for light and dark bars across the web at plate or anilox pitch.

    CAUSES, MOST LIKELY FIRST

  1. Impression above kiss on a job with a large solid next to open areaExcess pressure sets up a torsional oscillation in the print cylinder that prints as a repeating band.
  2. Plate mounting tape wrong for the workTape hardness is a suspension setting; a soft tape under a heavy solid lets the plate move at the nip.
  3. Worn gears, bearings or a loose cylinderMechanical backlash lets the cylinder accelerate and decelerate once per revolution.
  4. Solid and halftone on the same plateThe contact area changes through a revolution, so the load on the cylinder changes with it.
  5. Web tension too low into the printing nipA slack web lets the substrate move independently of the cylinder.
UV Flexo InksBars or bands across the web on solids

Fault 16 of 20  ·  continued

Bars or bands across the web on solids

CHECK, IN THIS ORDER

  • Measure the band spacing on the print and compare it with plate and anilox circumference to identify which cylinder is responsible.
  • Back the impression off to a kiss on that deck alone and rerun the section.
  • Check the tape specification against the job; record what is fitted.
  • With the press isolated, rock the cylinder by hand and feel for backlash.
  • Run the same plate at three speeds and record whether the banding moves or disappears.

THEN CHANGE

  • Reset impression to a kiss on every deck, starting from zero contact.
  • Change to a harder mounting tape under heavy solids and a softer one under fine halftone.
  • Separate solids and fine halftones onto different plates or different decks where the job allows it.
  • Raise web tension into the nip to the press setting sheet.
  • Report backlash for mechanical attention rather than trying to print around it.

CONFIRM IT IS FIXED

A clean solid with no visible banding on 200 m at production speed, at a kiss impression, at the speed the job will actually run.

THE TRAP

Adding impression to press the bands out. Impression is what excites the oscillation, so more of it makes the banding heavier, adds dot gain and wears the plate at the same time.
UV Flexo InksBars or bands across the web on solids (continued)

Fault 17 of 20

Colour to colour register drifts through the run

WHAT YOU SEE

Register is set at start-up and holds for a reel, then the last colours walk. Fine reverse text fringes, a keyline shows white on one side, and the operator is correcting register every few hundred metres. Worst on thin PE and on shrink film, and often in one direction only.

WHAT IT LOOKS LIKE

COLOURS IN REGISTER5 mmREGISTER WALKING OFF5 mmLoupe the reverse text and keylines: look for a white edge on one side as the last colours walk.

    CAUSES, MOST LIKELY FIRST

  1. Web tension walking as the reel diameter changesUnwind and rewind torque change through a reel, so a tension set at full diameter is a different tension at the core, and a film that stretches under tension carries that change into register.
  2. Film stretching because the web is running warmA web that has picked up 20 to 40 C under the lamps is longer and softer than the same web cold, so register set on a cold start-up walks as the press warms.
  3. Plate mounting or sleeve seatingA plate lifting at the lead edge, a bubble under the tape or a sleeve not fully home on the mandrel moves the image a fraction of a millimetre per revolution, and it moves further as the tape warms.
  4. Chill roller or idler dragA roller that is not turning freely puts a local tension step into the web between two decks, which the register system then chases.
  5. Impression above kiss on one deckExcess impression pushes the web forward at the nip and lengthens the distance to the next deck, and the amount it pushes changes with speed.
UV Flexo InksColour to colour register drifts through the run

Fault 17 of 20  ·  continued

Colour to colour register drifts through the run

CHECK, IN THIS ORDER

  • Read register off the printed register marks with a linen tester or the press camera at three reel diameters, and record web tension and web temperature at the same three points.
  • Run the press at two speeds and record whether the drift follows speed, which points at impression and tension, or follows time, which points at temperature.
  • Check every plate and sleeve for lift, bubbles and seating with the press isolated, and check the tape specification against the job.
  • Spin every idler and chill roller by hand with the press isolated and feel for drag or a flat spot.
  • Back each suspect deck to a kiss impression on its own and rerun the section.

THEN CHANGE

  • Set tension and taper to the setting sheet for the substrate and hold it, rather than correcting register against a tension that is still moving.
  • Bring web temperature down with the chill rollers and cold-mirror reflectors before chasing register on thin PE and shrink film; register and web temperature are the same fault on these substrates.
  • Remount plates that show lift or bubbles, and seat sleeves fully before blaming the press.
  • Free or replace dragging rollers, and report bearing drag for mechanical attention.
  • Reset impression to a kiss on every deck, starting from zero contact.

CONFIRM IT IS FIXED

Register held inside the agreed tolerance, typically plus or minus 0.1 to 0.2 mm for this class on filmic narrow web, across three consecutive reels at production speed and at the recorded tension and web temperature, with no operator correction in that length.

THE TRAP

Correcting register on the console every time it moves. It hides the drift rather than removing it, the corrections accumulate through the reel, and the start of the next reel is then set from a position that was never right.
UV Flexo InksColour to colour register drifts through the run (continued)

Fault 18 of 20

Colour does not match the approved proof, or shade moves between batches

WHAT YOU SEE

The job is on density and the solids look clean, but the customer rejects the shade, or reel three does not match reel one, or the same job printed last month looks different. The operator has already asked for a new batch of ink.

WHAT IT LOOKS LIKE

MATCHES THE STANDARD5 mmSHADE DRIFTED OFF PROOF5 mmLay the print beside the approved proof in D50 and read the drift in shade, not just density.

    CAUSES, MOST LIKELY FIRST

  1. Density and tone value read without fixed measurement conditionsStatus, geometry, polarisation and backing all move the number, so two readings taken differently disagree by more than the shade difference being argued about.
  2. Anilox volume and film weight, not ink shadeShade in flexo is laid-down weight of the same pigment. A plugged or worn roll shifts the shade before it shifts the density enough to notice.
  3. Substrate white point, opacity or gloss changedThe same ink over a whiter, more opaque or glossier stock reads as a different colour, and on clear film the shade depends on the white under it.
  4. Metamerism between the proof and the printTwo colourants that match under one illuminant separate under another, so a match under press-room light fails under the customer's light.
  5. Overprint varnish changed or missingThe coating changes gloss and therefore the measured and the perceived colour, so a print judged uncoated will not match the coated pack.
UV Flexo InksColour does not match the approved proof, or shade moves between batches

Fault 18 of 20  ·  continued

Colour does not match the approved proof, or shade moves between batches

CHECK, IN THIS ORDER

  • Fix and record the measurement conditions before arguing about colour: density status to ISO 5-3, 45/0 geometry to ISO 5-4, polarising filter stated, same white backing, and tone value increase from the same strip to ISO 12647-6. Report colour difference in CIEDE2000 and state the illuminant and observer.
  • Read the same patch on the approved print and on the reel with the same instrument at the same conditions, rather than comparing two instruments.
  • Check anilox cell condition at 100x and audited volume, and weigh the applied film against the approved run.
  • Measure the substrate: white point, opacity and gloss against the reel that was used for the approval, and check whether the white under a clear film has changed.
  • View the print and the proof under the customer's specified illuminant as well as under press-room light, and record whether the pair separates.

THEN CHANGE

  • Bring the measurement conditions into line first, and re-judge before touching anything on the press.
  • Restore anilox volume and film weight to the approved run by cleaning or changing the roll, not by impression or by temperature.
  • Match on the customer's own substrate and construction, including the white and the overprint varnish, rather than on a press-room stock.
  • Where a pair is metameric, take it back to the colour build rather than to the press, and agree the illuminant with the customer in writing.
  • Question the ink batch last, and when you do, send the batch number, the retained sample and the drawdown conditions with the complaint.

CONFIRM IT IS FIXED

Densities, tone values and CIEDE2000 colour difference inside the agreed tolerance on the customer's own construction, read at the recorded measurement conditions and under the agreed illuminant, held across three consecutive reels.

THE TRAP

Changing the ink batch first. It replaces a variable that was almost certainly not the cause, it loses the only fixed reference in the job, and the shade moves again on the next reel for the same anilox reason.
UV Flexo InksColour does not match the approved proof, or shade moves between batches (continued)

Fault 19 of 20

Paper and board label stock picks, lints and speckles the print

WHAT YOU SEE

White specks or bare spots in the solid on a paper face stock, fibre and dust building on the plate and in the chamber, and a solid that gets dirtier through the reel. The same plate and ink run clean on film.

WHAT IT LOOKS LIKE

CLEAN SOLID LAYDOWN5 mmPICKED AND SPECKLED SOLID5 mmLook across a solid on paper stock for white specks and bare spots building through the reel.

    CAUSES, MOST LIKELY FIRST

  1. Surface strength of the face stock below what the nip demandsA UV flexo ink is tacky and does not wet a fibre the way a fluid ink does, so the split at the nip lifts fibre and coating off a weak or poorly sized stock.
  2. Impression above kissEvery extra step of impression raises the split force at the nip, and picking rises with it faster than density does.
  3. Dust and lint from slitting and die-cutting carried back to the deckLoose fibre from the edges and from the matrix travels on the web and under the blade, where it plugs cells and rides under the edge.
  4. Uncoated or heavily embossed stock run at a process anilox volumeA rough surface needs a heavier lay to close, and a light lay on a rough stock reads as speckle rather than as low density.
  5. Ink temperature low, so tack is highA cold ink is more viscous and tackier at the split, and the coldest ink of the day is at start-up, which is when picking complaints start.
UV Flexo InksPaper and board label stock picks, lints and speckles the print

Fault 19 of 20  ·  continued

Paper and board label stock picks, lints and speckles the print

CHECK, IN THIS ORDER

  • Print the same plate and ink on a filmic stock. If it runs clean, the fault is the paper surface, not the ink or the deck.
  • Look at the plate and the chamber after 500 m for fibre and dust build, and strain the returning ink through a fine mesh.
  • Back the impression to a kiss on the affected deck alone and rerun the section.
  • Ask the stock supplier for the surface strength of the face stock and for a pick resistance figure from a printability tester, and compare the reel with the reel that ran clean.
  • Read ink temperature at the chamber at start-up and at running speed, and check web cleaning and extraction at the unwind and after the die station.

THEN CHANGE

  • Reset impression to a kiss on every deck before anything else; picking is an impression fault far more often than an ink fault.
  • Move to a stock with the surface strength for the job, or to a coated face stock, and take the matter up with the stock supplier with the printability data.
  • Fit or repair web cleaning at the unwind and after the die station, and extract dust at the slitters.
  • Raise anilox volume on rough and uncoated stocks rather than raising impression to close the solid.
  • Bring the chamber up to the 18 to 28 C band before running, so the first reel is not the tackiest one.

CONFIRM IT IS FIXED

A clean solid with no picking or speckle on 200 m at production speed at a kiss impression, with the plate and chamber clean of fibre at the end of that length.

THE TRAP

Raising impression to fill the speckle. Impression is what lifts the fibre, so the solid gets dirtier, the plate wears, and the dust that comes off goes into the chamber and plugs the anilox as well.
UV Flexo InksPaper and board label stock picks, lints and speckles the print (continued)

Fault 20 of 20

Rub and scuff resistance fails on the finished label

WHAT YOU SEE

The print marks in a rub tester or in transit, the colour comes off on a white cloth, or the label scuffs in downstream handling and on the filling line.

WHAT IT LOOKS LIKE

PASSES THE RUB TEST5 mmSCUFFS AND MARKS OFF5 mmRub with a white cloth and check for colour transfer and for scuff marks through the print.

    CAUSES, MOST LIKELY FIRST

  1. Under-cure, usually at the surfaceResistance is a direct function of cross-link density; a partly cured film has no chemistry to resist abrasion with.
  2. The sample was tested before cure-outCross-linking continues for hours after the lamp, so a rub figure read at the delivery under-reads the finished product and can reject a job that would have passed.
  3. No overprint varnish, or the wrong oneThe matched coatings are function-specific: SRC 89RC is the highest scratch and scuff resistance grade in the UniCure narrow-web coating range, HMR 70RC is the high-rub matt, and a general gloss is neither of them.
  4. Coefficient of friction too high for the handling line, or film weight too heavy for the dose availableA high-friction surface abrades itself against guides and against the next label, and the extra thickness that the dose cannot reach is the part that sits exactly where the rubbing happens.
  5. Matt finish specified without a high-rub gradeMatting agent sits proud at the surface and abrades unless the coating is built for it.
UV Flexo InksRub and scuff resistance fails on the finished label

Fault 20 of 20  ·  continued

Rub and scuff resistance fails on the finished label

CHECK, IN THIS ORDER

  • MEK double rubs following ASTM D5402 with the house method recorded, including the 1 kg load and the cloth, looking for at least 30 with no breakthrough. Read a press-side figure at the delivery as a cure check, and read the acceptance figure 24 h after cure at 23 C and 50 % RH once cross-linking has completed. State which of the two a reported number is.
  • Rub test on a Sutherland-type tester at the load and cycle count the customer specifies, dry and wet, on the cured-out sample.
  • Gloss to ISO 2813 at 60 degrees, and at 20 degrees where a high gloss is specified, to confirm the coating is there and at weight.
  • Coefficient of friction to ASTM D1894, static and dynamic, against the actual contact surface.
  • Weigh the coating: 1.5 to 3.0 g/m2 is typical for a UV overprint coating.

THEN CHANGE

  • Bring cure to the grade minimum first; no coating will rescue an under-cured ink underneath.
  • Test at the right time before rejecting a reel: a press-side figure is a cure check, not the acceptance figure.
  • Specify the matched coating for the duty: SRC 89RC for maximum scratch and scuff, HSC 81RC where a very low coefficient of friction is needed, HMR 70RC for a high-rub matt specified below 20 GU at 60 degrees.
  • Bring coating weight up to specification by anilox change rather than by pressure, and reduce ink film weight to the minimum that holds density so the dose available cures it fully.
  • Review the handling line for guides and brushes that are doing the damage.

CONFIRM IT IS FIXED

The customer's own rub specification passed on the finished construction 24 h after cure, plus 30 or more MEK double rubs by the house method following ASTM D5402 and gloss to ISO 2813 at the stated angle inside the agreed band.

THE TRAP

Adding wax or slip to the ink instead of specifying the coating. It improves the rub tester result and destroys the key for any varnish, foil or adhesive that has to go on afterwards, and it usually shows up as a lamination or foiling failure on the next job that uses the same ink.
UV Flexo InksRub and scuff resistance fails on the finished label (continued)

03

At the press

One page to work from, and the methods behind every number.

Quick reference

One page at the press

SymptomCheck this firstChange this first
Tacky surface, hard underneathConsole first: lamps lit, station power, line speed against the commissioned figureRelight or reset the station, then clean optics and close lamp distance; do not slow the press
Ink lifts on tape test, filmic stockTest inks on the reel, both edges and centreRaise in-line corona to 40 to 44 mN/m at running speed
Density dropping through the runAnilox cells at 100x on the running bandDeep-clean the anilox; reset blade to lightest clean wipe
Streak or line in the solidTrack the blade laterally with the press running: does the line move with itNew blade at the correct angle and minimum load, fitted with the press isolated
Shadows plugged, reverse text filledImpression, backed off to first complete solidReset to kiss impression on every deck
Pinholes or fisheyes on filmIsopropanol wipe test on a suspect stripClean the web path; check treatment is 40 to 44 mN/m, not higher
White not opaque on clear filmAnilox ruling paired with its own volume, 120 l/cm at 10 to 12 cm3/m2 or 180 l/cm at 7 to 9Correct anilox, then move white to 395 or 405 nm
Ink gelled in chamber or pumpWalk the ink line for stray light, hot surfaces and any sealed or completely full sectionShield the line, scrap the gelled ink safely, refill fresh
UV Flexo InksQuick reference

Quick reference

One page at the press

SymptomCheck this firstChange this first
Varnish or foil will not keyInterstation dose on the deck belowPin rather than cure out the layer below, except on FP low-migration work; use the matched OPV
Reel blocks or sets offMEK rubs on the last colour, web temperature at rewindFix the cure, then reduce rewind tension and cool the reel
LED deck will not cureIs the ink an LED grade, and is the head UV-A bandChange to UniCure LED 395 and refit the correct radiometer head
Odour or taint on low-migration workDose against the 150 to 250 mJ/cm2 UV-A band, and whether any deck was pinnedCure every deck out; audit every layer in the construction
Sleeve print cracks in the tunnelSeam area against a sample 50 mm away, then MEK rubs for over-cureCut seaming solvent where it is seam-located; otherwise reduce dose to the grade minimum
IML double-pick or curlMagazine, vacuum cups and die-cut edge, then static field meterCorrect the moulding line; apply ASC 88RC where static is the limit
Lamitube print crazes at the seamWhich OPV is on the job, by code on the drum labelFit the matched flexible lamitube coating and lighten the film at the seam
Bars or bands across the webBand spacing against plate and anilox circumferenceBack that deck to a kiss impression alone
UV Flexo InksQuick reference

Quick reference

One page at the press

SymptomCheck this firstChange this first
Register walks through the reelTension and web temperature at three reel diametersHold tension and taper to the setting sheet and cool the web before correcting register
Shade off proof or between batchesMeasurement conditions: status, geometry, polarisation, backingFix the conditions and re-judge; check anilox and film weight before the ink batch
Speckle and picking on paper stockRun the same plate on film: does it run cleanReset to kiss impression, then raise anilox volume rather than pressure
Rub or scuff failure on the labelWas the rub read at the delivery or 24 h after cureRetest cured out, then bring cure to the grade minimum and fit the matched coating
UV Flexo InksQuick reference

Test methods

The measurements this guide relies on

MeasurementMethodWhat it tells you, and the usual acceptance
UV radiometry, dose and peak irradianceNo single test standard; use a band-calibrated instrumentThe only honest measurement of what the film receives. A band-matched head is carried through the press at running speed and read on the heaviest solid, giving dose in mJ/cm2 and peak irradiance in W/cm2. Typical for this class: 80 to 150 mJ/cm2 UV-A for process colours, 150 to 250 for opaque white and low-migration sets, at 1 to 2 W/cm2 UV-A peak under a focused 120 to 160 W/cm mercury lamp. A four-band head at mercury stations shows short-wave loss as a falling UV-C to UV-A ratio against the commissioning trace. A UV-A head is required at 385 to 405 nm LED stations; a broadband head does not report what an LED array delivers.
MEK double rubsASTM D5402, with the house method recorded alongside itSolvent resistance as a proxy for cross-link density, and the fastest cure check at the press. ASTM D5402 describes the practice but does not fix the load or the cloth, so the house method is recorded with every result: cloth type, a 1 kg load, methyl ethyl ketone, and one forward and back stroke counted as one double rub. Acceptance for this class: at least 30 double rubs with no breakthrough to the substrate. A figure read at the delivery is a cure check; the acceptance figure for rub and scuff duty is read 24 h after cure at 23 C and 50 % RH. Gloves, eye protection and a ventilated bench away from lamps and ignition sources.
Cross-cut adhesionISO 2409Classifies adhesion by cutting a lattice through the film and pulling a specified tape across it. Use 2 mm cut spacing on flexible film substrates and 1 mm only on hard substrates, following the substrate and thickness table in the standard, and name the tape and its adhesion value on the report. Read 24 h after cure at 23 C and 50 % RH, never at the delivery. On a 1 to 2 micron ink over film the cut can dig into the substrate and the classification stops meaning anything, so where that happens agree a straight tape pull or a snap test on the customer's own material instead. Adhesion is a property of the ink to substrate interface, so the acceptance is agreed with the customer on their own material.
Wetting tension, test inksASTM D2578, equivalently ISO 8296Surface energy of the substrate, read at two seconds on the reel about to run. Target 40 to 44 mN/m on corona-treated PE and PP. Below 38 mN/m, adhesion and resistance both fall away, and this is the single most common cause of a failed label. Test the unprinted back of the web as well: backside treatment is the reliable marker of overtreatment.
GlossISO 2813Specular gloss at 60 degrees for general comparison, and at 20 degrees where a high gloss is specified. Quote the angle with every figure, because the same film reads differently at each. Used to confirm the overprint varnish is present and at weight: a high-gloss UV overprint varnish at 2.0 to 3.0 g/m2 typically reads 85 to 95 GU at 60 degrees and 65 to 85 GU at 20 degrees on filmic stock, while a matt grade such as HMR 70RC is specified below 20 GU at 60 degrees. Read on the same substrate every time, because the stock under the varnish moves the number as much as the coat weight does.
Coefficient of frictionASTM D1894Static and dynamic friction of the finished face against the surface it will actually touch. Decides whether labels slide through downstream handling, whether IML labels single-pick, and whether a reel will dispense. Balance between the two faces matters more than the absolute figure.
Lightfastness, blue woolISO 105-B02Fade resistance of the pigment on a one to eight scale against dyed wool references under a xenon arc. UniCure HF is formulated on high light-resistance pigments rated blue wool 6 to 8 for outdoor labels, sacks and chemical packs. Blue wool rates pigment fade under a xenon source and nothing else: it is not a durability figure and must not be quoted as one.
UV Flexo InksTest methods

Test methods

The measurements this guide relies on

MeasurementMethodWhat it tells you, and the usual acceptance
Accelerated weatheringISO 4892-2Xenon-arc exposure with water spray and controlled temperature and humidity, run on the customer's complete construction including substrate, adhesive and overprint varnish. This, not blue wool, is what addresses weathering, moisture, thermal cycling and the abrasion an outdoor label meets, and the result is correlated with the customer's field expectation rather than quoted as a service life.
Applied film weight, differential weighingNo standard number; weigh printed against unprintedA known area of printed web is cut and weighed against the same area of unprinted web on a four-place balance. Typical for narrow-web flexo: 1.2 to 2.0 g/m2 for process colours, 1.5 to 3.0 g/m2 for a UV overprint coating. It is the number that connects anilox volume to both density and curability.
Rotational viscosityRecord the conditions; a flow cup is not valid hereViscosity measured on a rotational viscometer at 25 C with the spindle and speed recorded every time, because a UV flexo ink is shear thinning and a reading without its conditions means nothing. Series typical at 25 C: process colours approximately 500 to 1200 mPa.s, opaque whites approximately 1200 to 2500 mPa.s, and UniCure Tube pumpable at 800 to 2000 mPa.s and above on peristaltic pumps. An ISO 2431 flow cup is a water-based and solvent-based tool and will not give a usable reading on these inks. 1 cP equals 1 mPa.s.
Density and tone value increaseISO 5-3 and ISO 5-4 for the measurement conditions, ISO 12647-6 for flexographic tone valueSolid ink density and tone value read on a control strip with the conditions fixed and recorded: density status to ISO 5-3, status E for European work or status T where the customer specifies it, 45/0 geometry to ISO 5-4, polarising filter stated on or off, and the same white backing every time. Report colour difference in CIEDE2000 with the illuminant and observer stated. Without these conditions two operators on the same press disagree by more than the fault they are chasing.
Sensory assessment, closed jarDIN 10955The closed-jar Robinson test on printed and converted material against unprinted substrate as the reference, with a trained panel, the storage time and temperature stated, and the result on the 0 to 4 scale. Where the brand owner has their own sensory method, run theirs and report against their acceptance. A sensory pass is a sensory result only; it is not a migration result.
UV Flexo InksTest methods

When the press-floor fixes have not worked

What to send us

  • The radiometer trace: dose and peak irradiance in the UV-A band, and the UV-C band as well at mercury stations, taken through the press at running speed on the heaviest solid, with the head type, the calibration date and the lamp or array hours written on it.
  • Printed samples from the fault, unconverted and still in the reel where possible, plus a good sample from the same job for comparison, wrapped in aluminium foil and not in plastic bag film.
  • One metre of the unprinted substrate from the same reel, with the reel number, the resin or face-stock grade, the treatment level on the day of printing and whether any recycled content is in the printed face.
  • The full construction by grade code: every ink, white, primer, overprint varnish, adhesive and laminate in the pack, in the order they are applied, including anything the converter adds off line.
  • The press settings sheet for the job: anilox ruling and volume by deck in one unit system, plate type and relief, mounting tape, impression and blade load settings, line speed, web and chill roller temperatures, web tension and taper, and rewind tension.
  • The ink batch numbers from the 5 kg packs, the date they were opened, and the store temperature; the range carries a 6-month shelf life unopened in the original pack.
  • For any colour complaint, the approved print or proof, the instrument used and the measurement conditions it was read at: density status, geometry, polarisation, backing and illuminant. A shade argument without these is not a measurement.
  • The end-use specification the print has to meet, and the customer's own test method and acceptance for it, so the trial is judged against their pack and not ours. Adhesion, migration, bond strength and seal performance are qualified on the customer's construction, not on the ink.
Technical servicesales@ufindustries.com  |  +91 8750051884  |  E105, GNEPIP, Industrial Area Site-5, Greater Noida, Uttar Pradesh 201306, India
UV Flexo InksTechnical service
1