Troubleshooting guide
Press-floor fault finding for Uniforce-250 mercury UV and Unimax 400 UV LED offset on sheet-fed and combination presses.
Uniform Industries · Greater Noida, India · ufindustries.com
Figures are typical for the class and carry their test method. The values that govern a supply are those on the Technical Data Sheet for the grade.
Before you start
Work down the page. Cheap checks before expensive ones, and measure before you change anything.
01
What happens, in order, and the one variable held at each step.
The process
Control variables
| Variable | Target | How it is measured | How it drifts |
|---|---|---|---|
| Fount conductivity | Make-up specification for a fresh tank: base water + 900 to 1300 uS/cm at 25 C. Running tolerance once the job has started: +/- 200 uS/cm on the figure that job actually started at, logged beside the incoming water reading | Calibrated conductivity meter at the fount tank, incoming mains water read on the same meter at the start of the shift | Climbs steadily through a run as calcium carbonate and coating binder come off the board into the circulation. A climb of 300 uS/cm above the start-of-job reading is a refresh, even when the absolute figure still sits inside the make-up window, which is exactly why the start-of-job figure is logged. The absolute number means nothing unless the incoming water was logged. |
| Fount pH | 4.8 to 5.5 | pH meter calibrated on 4.0 and 7.0 buffers at 25 C, read at the tank, not on paper strips | Rises as alkaline coating dissolves into the tank. The desensitising film on the plate fails while the meter still reads inside the window, so read pH and conductivity together and treat a climbing pair as one signal. |
| Fount temperature | 10 to 14 C at the tank | Thermometer at the tank outlet, not the chiller set point | Creeps up through a long run as the chiller falls behind the heat the lamps put back into the press. Every 2 C of rise behaves like a step of extra alcohol taken out, and the operator sees it as scumming. |
| Roller train temperature | 28 to 32 C surface | Non-contact IR thermometer on the roller face at three positions across the width after 500 sheets at speed. Never bring a contact probe, a hand, a rag or a strip into a moving roller train. If a contact reading is needed, stop the press, isolate and lock it off, and read within a few seconds of stopping | Rises in the first twenty minutes and again after every stop and restart. Above about 35 C the ink body drops, the ink takes water it should not take, and density falls without anyone moving a key. |
| Ink duct temperature | 22 to 28 C | Probe in the ink body in the duct, away from the duct blade, with the press stopped and isolated | Tracks the room and the lamp housings. A duct sitting at 32 C on a summer afternoon runs a different ink from the one specified, and the tack ladder built at the house temperature no longer describes it. |
| Dose at the substrate | 80 to 150 mJ/cm2 process colours, 120 to 200 mJ/cm2 dense black, 150 to 250 mJ/cm2 opaque white and metallics | Band-calibrated radiometer, UV-A 320 to 390 nm for Uniforce-250 or 385 to 405 nm for Unimax 400, passed through the press on a carrier sheet at running speed, per unit. Record the lamp rating in W/cm, or the array wavelength and rating, beside every reading | Falls with lamp age, reflector fouling, quartz devitrification and ink mist on the LED window. The loss is gradual and invisible until a job with a narrow window fails, so trend it against the commissioning figure rather than waiting for a complaint. |
| Peak irradiance at the sheet | Mercury, Uniforce-250: 1 to 3 W/cm2 UV-A at the sheet, quoted with the lamp rating, typically 1 to 1.5 W/cm2 from a 120 W/cm system and 2 to 3 W/cm2 from a 200 W/cm system, both on a clean reflector at the correct focus. LED, Unimax 400: 8 to 12 W/cm2 process, 12 to 16 W/cm2 under opaque white and dense black | Same radiometer pass, reading peak rather than integrated dose, with the lamp rating in W/cm or the array rating recorded alongside | Changes with lamp-to-sheet distance, reflector condition and focus. It is the number that beats oxygen inhibition, and it is the one operators never look at because the console only offers them a percentage. It is set by the source and its geometry and does not change with press speed, so trend each press against its own commissioning reading rather than against the published range. |
Control variables
| Variable | Target | How it is measured | How it drifts |
|---|---|---|---|
| LED array working distance | 5 to 15 mm sheet-fed, 2 to 8 mm interdeck, to the array maker's figure | Feeler gauge or shim at three positions across the array, cold, with the press stopped, isolated and locked off | Opens up when packing is changed, when a transfer cylinder jacket is replaced, or when someone lifts the array for cleaning and does not return it. Five millimetres of extra gap typically costs 15 to 30 % of peak irradiance. |
| Tack ladder across the sequence | 16 +/- 1 first down descending to 12 +/- 1 last down, 1 to 2 points per unit, on the inkometer scale | Inkometer to ASTM D4361, 1200 rpm, 32 C, 1.32 cm3 charge, read at 60 s, the house method across the whole range. These are inkometer-scale numbers. An IGT Tack-o-scope or any other instrument reads on its own scale and its figures cannot be compared with these; print the instrument, speed, temperature, charge and read time beside any tack figure you quote back to us | Does not drift in the tin, but drifts on press as duct and roller temperature move. A ladder measured at a different charge, speed, temperature or instrument is not comparable with the published figure and must not be used to argue with it. |
| Emulsification, water pick-up | 15 to 25 % w/w on Uniforce-250 at the house conditions, typical for a sheet-fed UV offset ink and far below an oil-based ink | Duke-type incremental water addition on the inkometer at 1200 rpm and 32 C, the same conditions as the house tack method, water added in weighed increments to the end point, pick-up reported as % w/w with the conditions attached | Water uptake is strongly temperature dependent, so a figure quoted without its temperature and its water-addition schedule cannot be argued with. A duct sample taken at the end of a run and compared against a fresh tin on the same conditions is the only useful comparison. |
| Film weight on a solid | 1.0 to 1.5 g/m2 process on coated stock, 1.8 to 2.5 g/m2 opaque white, 1.5 to 2.5 g/m2 metallics | Gravimetric, but taken so that board variation does not swallow the answer: cut a known area of at least 100 cm2 of solid and an equal area of unprinted stock from the same sheet, side by side and at the same position across the sheet, weigh both on a four-place balance and take the difference. Average at least three pairs. Do not weigh a printed sample against unprinted stock from a different sheet or a different pallet: board basis weight varies by several g/m2 within a pallet, which is more than the whole ink film being weighed. Cross-check against ink consumption per thousand sheets, which is what catches a systematic error in the weighing | Climbs when an operator chases density on a tired blanket or on absorbent stock. It is the single variable that most changes cure at depth, set-off, crease performance and, on the LM grade, migration risk. |
The mechanism
A cross-section through a printed UV film, top to bottom. The same film can be tacky at the surface and liquid at the board while being perfectly hard in the middle, and the two failures have opposite cures. Oxygen starves the top and is beaten by peak irradiance, the light per unit time, which the lamp and its geometry set and press speed does not. Pigment starves the bottom and is beaten by wavelength and by a thinner film. Neither is beaten by running slower, which is the first thing every operator reaches for.
02 | 20 faults
Symptom, cause, check, change, confirm. The trap is the move to avoid.
Fault 1 of 20
WHAT YOU SEE
The clear areas of the sheet pick up a wash of colour that deepens through the run, worst in the middle of the sheet and worst after a stop. The operator opens the water, the tint clears for a few hundred sheets, then the solids go flat and the fault comes back.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 1 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
The open areas stay clean at a dampening setting at or below the one that held density at the start of the run, with conductivity inside +/- 200 uS/cm of the start-of-job figure and pH 4.8 to 5.5, and solid density back in spec on Status E to ISO 5-3.THE TRAP
Opening the water. It clears the tint for a hundred sheets and then over-emulsifies the ink. Uniforce-250 carries only 15 to 25 % w/w water at the house conditions, far less than an oil-based ink, so the operator arrives at a flat, greasy, poorly trapping ink and now has two faults to unpick instead of one.Fault 2 of 20
WHAT YOU SEE
Scratch the solid with a gloved thumbnail and the film is solid, but a firm gloved thumb twist marks it and the gloss mattes where you touched it. Highlights and light tints feel tackier than the solids. The pile blocks by the morning.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 2 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Gloved thumb twist clean at one minute, at least 20 IPA double rubs clean at five minutes, and at 24 hours at least 50 MEK double rubs on process solids and at least 30 on opaque white to ASTM D5402.THE TRAP
Slowing the press. Peak irradiance at the sheet is fixed by the lamp or the array and its geometry, not by press speed, so slowing raises total dose while leaving the radical generation rate at the surface exactly where it was, and it gives oxygen longer to diffuse into the film during exposure. The tacky surface gets no better and often gets worse, and the speed is lost as well. The one exception is a press that tracks lamp power to running speed: those lamps do drop power as the press slows, which lowers irradiance as well.Fault 3 of 20
WHAT YOU SEE
The process colours are hard and the white on the same sheet is hard on top but lifts in a sheet when you pick at an edge, or shows a soft, cheesy layer against the board. Odour in the pile. On a reverse-printed job, everything printed over the white fails with it.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 3 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
The white cannot be lifted from the board with tape 24 hours after the run, a tape pull across a scored area takes no ink, at least 30 MEK double rubs on the white to ASTM D5402, and no residual acrylate odour in a closed sample bag opened under extraction at 24 hours. Keep the ISO 2409 cross-cut classification for plastic and metallised substrates: on coated carton board the blade cuts through into the board coating and what lifts is coating and fibre, so the classification does not describe the ink film and cannot be used as an acceptance.THE TRAP
Adding dose at the same wavelength. More exposure time at 365 or 395 nm sends more photons to a layer that has already absorbed them, so the top gets harder and more brittle while the interface stays wet. The fix is film weight, dose on the right unit and wavelength, not time.Fault 4 of 20
WHAT YOU SEE
The job passes at the press and the converter finds soft, set-off or scuffed sheets scattered through the middle of a pallet rather than at the top or the bottom. The sheets either side of them are perfect. On a job that stopped often, the bad sheets are spread through every pallet.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 4 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Sheets taken at 10, 30 and 100 sheets after a restart give at least 20 IPA double rubs clean at five minutes and at least 50 MEK double rubs to ASTM D5402 at 24 hours, matching sheets taken from the middle of the run.THE TRAP
Judging the restart sheets by eye. An under-cured sheet at the delivery looks exactly like a cured one, the fault is found at the converter weeks later, and by then it sits in the middle of every pallet on the job and the whole run is suspect rather than a hundred sheets of it.Fault 5 of 20
WHAT YOU SEE
The second colour looks weak and mottled over the first, greys and neutrals go dirty, and a reversed sequence proof from the same inks looks correct. Wiping the sheet shows the second colour sitting loose on the first rather than keyed into it.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 5 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Measured tack descends by 1 to 2 points per unit in running sequence on the house inkometer method, the overprint solid reads to the agreed density on Status E, and a hand overprint of the same inks on the same stock matches the press sheet.THE TRAP
Reducing the tack of the offending ink on press with reducing varnish or a thin oil. It lowers tack and film strength together, so the ink traps a little better and then piles, mists and loses density and gloss, and the ladder is no longer the one anybody has a record of.Fault 6 of 20
WHAT YOU SEE
Two hours into the run the solids drop half a point with nobody touching a key, the ink in the duct looks curdled or buttery rather than glossy, and the operator opens keys to hold density, which makes it worse.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 6 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Solid density holds inside +/- 0.05 on Status E over 2000 sheets at constant key settings, duct ink water pick-up back inside 15 to 25 % w/w at the house conditions, and the ink regains its gloss in the duct.THE TRAP
Opening the keys to chase the falling density. It puts more ink into an emulsion that is already saturated, so the film gets thicker, cure at depth suffers, set-off starts in the pile, and the density still does not come back.Fault 7 of 20
WHAT YOU SEE
The back of each sheet carries a ghost of the sheet below, worst in the heavy solids and worst in the centre of the pile. On a bad pile the sheets stick and tear apart at the guillotine.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 7 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
A pile of 500 sheets stood overnight under its own weight shows no image transfer on the reverse, and the solid gives at least 50 MEK double rubs on process colours and at least 30 on opaque white at 24 hours.THE TRAP
Turning the powder up and carrying on. It masks the fault for one job and then takes the powder into the coater and the foiling unit, where it shows as pinholing and poor foil pick, and the uncured film is still uncured when the pack reaches the customer.Fault 8 of 20
WHAT YOU SEE
Solid density drops away over a few thousand sheets and the operator finds a dry, crusty build-up on the blanket in the solid areas, or a white deposit on the plate in the image. Wash up and it runs clean for another few thousand.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 8 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Solid density holds inside +/- 0.05 on Status E for a full pile with no wash-up, and the blanket is clean in the solid areas at the end of it.THE TRAP
Adding reducing varnish to drop the tack. It reduces the tack and the cohesive strength together, so the ink piles less on the blanket and more in the roller train, then mists at speed and loses gloss and density, and the tack ladder is no longer a known quantity.Fault 9 of 20
WHAT YOU SEE
Ink refuses to stay on one or two rollers and leaves bare rubber stripes, or the blanket has grown so that the impression has changed and the packing no longer measures what it did. Rubber feels soft and slightly sticky.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 9 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Roller diameters back to specification, hot nip readings even across the width, ink carrying evenly with no bare stripes, and the blanket measuring its nominal thickness under a dial gauge.THE TRAP
Increasing the nip pressure to force ink onto a stripping roller. It compresses a roller that is already swollen, heats the train further, accelerates the swell and adds slur and dot gain on the sheet, so the stripe disappears and three new faults arrive.Fault 10 of 20
WHAT YOU SEE
The job passes at the press and comes back from the die-cutter, the folder-gluer or the carton line with scuffed solids and grey marks along the running direction. Dark solids and heavy blacks show it first.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 10 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
The converted pack passes the customer's own line trial without marking, with scuff and abrasion measured to ASTM D5264 on that construction at an agreed load, stroke count and receptor, and agreed as the acceptance; quote coefficient of friction to ASTM D1894 alongside it where the complaint is marking on rails. At least 50 MEK double rubs at 24 hours on the marking solid.THE TRAP
Adding wax compound to the ink on press. It raises slip on the sheet, drops gloss and, on any panel that will be coated or foiled later, causes the coating to crawl and the foil to refuse. The scuff answer belongs in the coating, not in the ink duct.Fault 11 of 20
WHAT YOU SEE
The ink is hard and passes its rub test, and the layer on top of it fails: an aqueous or UV coating crawls, pinholes or pulls back off the solid, cold or hot foil refuses to pick in the printed areas, or a glue flap peels apart clean at the ink surface on the folder-gluer. It follows the heavy solids and the panels that cured hardest.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 11 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
The coating lays flat with no crawling or pinholing over every solid on the sheet, the foil picks cleanly at production speed, and the glued joint tears board fibre rather than peeling clean at the ink surface, on the customer's own board and adhesive. Bond strength and seal performance are properties of the construction and the interface and are qualified on that construction, not by the ink specification.THE TRAP
Adding dose because the coating is lifting. It is the same reflex as the adhesion fault and the same mistake: a harder, more crosslinked, lower-energy surface is exactly what the second layer cannot key into, so every step in that direction makes the coating, the foil and the glue worse while the ink rub test keeps passing.Fault 12 of 20
WHAT YOU SEE
Cross-hatch and tape pull takes the ink cleanly off the sheet in squares. The film is hard and glossy and MEK rubs pass, so the ink is cured; it simply is not attached. Often worse at the reel or pallet edges and worse on stock that has been in the warehouse.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 12 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Cross-hatch classification 0 to 1 to ISO 2409 with a tape pull at 24 hours, on the customer's own substrate from the same batch that will run. Adhesion is a property of the interface and the construction, and it is qualified by trial on that material rather than guaranteed by the ink specification.THE TRAP
Adding dose because the ink is coming off. Adhesion failure and cure failure look the same to an operator and the reflex is the lamp. On film, dose above the window raises cure shrinkage and interfacial stress, so the cross-hatch result goes from bad to worse while the MEK rubs keep passing. The answer is the window, the treatment and the grade, not more lamp.Fault 13 of 20
WHAT YOU SEE
Midtones go dark and muddy, the 50 % patch reads well over the curve, and a loupe shows the dot smeared in the running direction or printed twice slightly offset. Solids look acceptable, which is why it is missed until the proof comparison.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 13 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Tone value increase on the 50 % patch back inside the agreed curve for that stock and screen, measured to ISO 5-3 Status E, with a clean single dot under the loupe.THE TRAP
Pulling density out of the solids to compensate for the dark midtones. The curve is wrong, not the level, so the job ends up with weak solids and midtones that are still heavy, and the plate curve gets changed to hide a mechanical fault that then follows the press onto the next job.Fault 14 of 20
WHAT YOU SEE
A large solid or a heavy tint shows a cloudy, orange-peel or blotchy appearance that does not move with the sheet, and gloss varies across the same panel. Usually worst on silk and matt coated board and on recycled grades.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 14 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Gloss within +/- 5 GU at 20 degrees across the panel to ISO 2813 at 24 hours, and a visual match to the approved press sheet under the agreed viewing conditions.THE TRAP
Reaching for a gloss or levelling additive. On a 100 % solids ink these move the surface tension of a film that is already on the sheet, so they redistribute the mottle rather than remove it, and they carry into the next job on the same rollers.Fault 15 of 20
WHAT YOU SEE
A fine white line along the fold in a heavy solid or a heavy white, visible on the folder-gluer or in the carton on the customer's line. Runs along the score, worst across the board grain.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 15 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
A 180 degree fold on the finished board shows no white line under a loupe at 24 hours, on board creased with the production rule, folded in the production direction, and conditioned as it will be at the converter.THE TRAP
Adding dose because a cracked crease looks like a weak film. It is the opposite fault. More dose makes a harder, more brittle network and the crease gets worse with every step the operator takes to fix it.Fault 16 of 20
WHAT YOU SEE
A faint positive or negative image of a heavy solid repeats further down the sheet in a tint or a lighter solid, at a fixed distance that matches a roller circumference.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 16 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No visible ghost under the agreed viewing conditions on a pull from the middle of the run, with density on the affected tint even within +/- 0.03 along the sheet on Status E.THE TRAP
Opening the keys in the ghost band. It flattens the ghost at one running speed and then over-inks the band at every other speed, and it leaves the depleted roller untouched, so the fault returns the moment the press changes pace.Fault 17 of 20
WHAT YOU SEE
Lumps or a rubbery skin in the duct, or a hard film building on the ink train near the lamp end. The lumps will not disperse and print as hard specks. Often found at the start of a shift after the press stood with the lamps running.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 17 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
A fresh duct charge runs a full shift with no lumps, no skin on the train, and a grindometer reading to ISO 1524 at or below 7.5 micron for process and 12.5 micron for white and metallics at the end of it.THE TRAP
Straining the lumps out and carrying on. A gelled ink is a partly polymerised ink throughout, not a clean ink with lumps in it, so the strained material has already lost transfer, gloss and tack and will pile and print specks for the rest of the run.Fault 18 of 20
WHAT YOU SEE
A fine haze of ink on the press frame, on the guards and on the operator, appearing above a certain speed and worst on the lightest-tack units at the end of the sequence. That haze is airborne uncured acrylate, which is a skin and respiratory sensitiser, so it is an exposure event and not only a housekeeping nuisance.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 18 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No visible haze on the frame at full running speed over 5000 sheets, with measured tack back on the ladder figure for that unit on the house inkometer method.THE TRAP
Adding more reducer because the misting ink also looks weak. Every step in that direction lowers cohesion further, so the misting worsens while the operator believes they are fixing a body problem, and the ink ends the run outside every specification it arrived with, with more uncured acrylate in the air the whole time.Fault 19 of 20
WHAT YOU SEE
The printer sees nothing wrong. The complaint comes back from the packer or the brand owner: an acrylate smell in a closed carton, or a taint in a dry product filled into the pack. Almost always on a job with a heavy white or a dense black.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 19 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
No detectable odour in the sealed jar screen at 24 hours, cure confirmed at the specified dose and film weight. Beyond that, conformity is not established at the press: migration, food-contact suitability and any claim about the finished pack are assessed on the pack itself, on request, at the specified dose and film weight, on the actual substrate and with set-off controlled.THE TRAP
Treating an odour complaint as an ink formulation complaint and asking for a different ink. Odour in a cured UV film is almost always under-cure at depth, and a new ink run at the same dose under the same heavy white gives the same result a month later, with a job lost in between.Fault 20 of 20
WHAT YOU SEE
The sheet matches the approved proof at start-up and has walked away from it by the time the first pallet is off, usually toward weaker and greyer. The operator pulls it back with the keys, and it walks again after the next stop.WHAT IT LOOKS LIKE
CAUSES, MOST LIKELY FIRST
Fault 20 of 20 · continued
CHECK, IN THIS ORDER
THEN CHANGE
CONFIRM IT IS FIXED
Solid density holds inside +/- 0.05 on Status E to ISO 5-3 from the 500th sheet to the end of the run at constant key settings, with roller and fount temperature and fount conductivity logged inside their windows for the same period.THE TRAP
Resetting the keys at every deviation. It chases a moving process with the one lever that changes film weight, so the ink load ends up outside specification, cure at depth and set-off follow it, and nobody can tell afterwards what the job actually ran at.03
One page to work from, and the methods behind every number.
Quick reference
| Symptom | Check this first | Change this first |
|---|---|---|
| Tint or scum in the open areas | Fount conductivity, pH and temperature at the tank, against the start-of-job figure and the incoming water reading | Dump and remake the fount; correct roller temperature before touching the water setting |
| Tacky surface, hard film underneath | Peak irradiance at the sheet with the lamp rating recorded, and the short-wave bands against the commissioning figures | Raise peak irradiance: close the LED gap, clean the window, change the lamp. Do not slow the press |
| Soft or lifting film under opaque white | White film weight gravimetrically, then dose on the white unit alone | Cut film weight toward 1.8 g/m2 and correct the dose on that unit; then move the white to a gallium-doped lamp or a 405 nm array |
| Soft sheets scattered through the middle of a pallet | Rub-test the first hundred sheets after a deliberate stop, and read the dose immediately after a restart | Bin a fixed number of sheets after every stop and have the shutter and standby timing checked |
| Second or third colour will not trap | Tack of each duct in sequence order on the house inkometer method, 1200 rpm, 32 C, 1.32 cm3, 60 s | Put the graduated grades back in their intended units, 16 first down to 12 last down |
| Density falls, ink short and greasy | Water pick-up on a duct sample against 15 to 25 % w/w at the house conditions, and roller temperature | Dump the duct and the fount, restore 28 to 32 C, reduce dampening. Do not open the keys |
| Set-off or blocking in the pile | Gloved thumb twist and 20 IPA double rubs at the delivery, and pile centre temperature | Raise dose on the heaviest unit and take smaller piles |
| Piling on the blanket | Whether the build-up is on the blanket only or on plate and blanket together | Blanket only: drop first-down tack by grade. Both: dump and remake the fount |
Quick reference
| Symptom | Check this first | Change this first |
|---|---|---|
| Rollers stripping, rubber soft or swollen | Roller diameter against specification and the roller compound from the maintenance record, press isolated | Fit EPDM rollers and UV-compatible blankets. Nothing else works until this is done |
| Coating crawls, foil will not pick, glue lap peels clean | Surface energy of the cured ink film at the delivery and at 24 h, and the interdeck pinning dose | Cut pinning and bring final dose back inside the window. Do not add dose |
| Ink comes off plastic at cross-hatch | Surface energy with dyne pens or ISO 8296 test inks on the reel you are about to run | Re-treat or prime below 40 mN/m, and move to the UF250PL grade. Correct the dose to the window, do not add to it |
| Heavy dot gain, smeared dot | Packing with a dial gauge, and blanket thickness itself, press stopped and isolated | Reset packing to the press build; replace a swollen blanket |
| Mottle or patchy gloss in a solid | Whether the pattern repeats at a cylinder circumference; film weight gravimetrically | Raise film weight toward the top of the window for that stock, or back off a pinning lamp sitting close behind the nip |
| Cracking on the crease | Crease unprinted board on the same rule, check board moisture and storage, then check dose for over-cure | Condition the board and cut film weight; bring dose back inside the window. Do not add dose |
| Ghost repeating down the sheet | Repeat distance against roller circumferences; positive or negative ghost | Reduce film weight on that unit and reset roller nips hot |
| Odour in the closed carton | Sealed jar at 40 C for 24 h, opened under extraction, then dose on the white and black units | Correct cure at depth and cut ink load. Do not change the ink grade first |
Test methods
| Measurement | Method | What it tells you, and the usual acceptance |
|---|---|---|
| Tack, house method | Inkometer to ASTM D4361, house conditions: 1200 rpm, 32 C, 1.32 cm3 charge, read at 60 s | Gives the tack figure the whole range is published on, and the only figure that can be compared with the tack ladder. These are inkometer-scale numbers: bench tack 13 +/- 2 for a single mid-sequence ink, and the sequence ladder is a separate specification, 16 +/- 1 first down to 12 +/- 1 last down on Uniforce-250. A reading taken at a different charge, speed, temperature or on a different instrument is a different number on a different scale and cannot be used to argue with the specification. An IGT Tack-o-scope in particular reads on its own scale and will not return these figures. Print the instrument, speed, temperature, charge and read time beside any tack figure quoted. |
| Emulsification, water pick-up | Duke-type incremental water addition on the inkometer, 1200 rpm, 32 C, the same conditions as the house tack method, water added in weighed increments to the end point | Reports water pick-up as % w/w with the conditions attached. 15 to 25 % w/w on Uniforce-250, typical for a sheet-fed UV offset ink and far below an oil-based ink. Water uptake is strongly temperature dependent, so the figure means nothing without its temperature and its addition schedule. The useful comparison is a duct sample against a fresh tin of the same batch on the same conditions. |
| Viscosity and yield value | ASTM D4040, falling-rod (Laray) viscometer at 25 C, reported at 2500 s-1 | The body of the ink as supplied. 45 +/- 15 Pa.s on Uniforce-250 and 45 +/- 10 Pa.s on Unimax 400, with a yield value of 150 +/- 50 Pa. A duct sample well outside this has been reduced, contaminated or over-emulsified on press. |
| Fineness of grind | ISO 1524 grindometer at 25 C | Checks dispersion and finds contamination or a ground-in skin. At or below 7.5 micron for process colours and bases, at or below 12.5 micron for opaque white and metallics. A duct sample that has coarsened during a run is the first evidence of gelling or dried ink returning to the duct. |
| Solvent resistance, cure check | ASTM D5402, MEK double rubs, cotton pad under about 1 kg hand load, worked in nitrile gloves with eye protection, under local extraction or in a well ventilated area, and well away from lamps, hot housings, heaters and any other ignition source | The decisive test for whether the film is cured. At 24 hours, after the dark reaction, at least 50 double rubs on process solids and at least 30 on opaque white. The five-minute IPA double rub check, at least 20 clean, is the press-floor screen that tells you whether to keep printing, and it is run under the same conditions. MEK and IPA are both highly flammable and MEK is readily absorbed through skin: keep containers closed, put used pads straight into a closed metal waste container, and read the safety data sheet before the first test. |
| Cross-cut adhesion | ISO 2409, cross-cut with a tape pull | Classification 0 to 1 typical at 24 hours on a properly treated plastic or metallised substrate, class 1 being detachment of not more than 5 % of the lattice area. Use it on substrates that do not fail before the ink does: on coated carton board the blade cuts through into the board coating and what lifts is coating and fibre, so the classification does not describe the ink film and should not be written into an acceptance. On board, use a tape pull across a scored area together with the MEK rub. It is a check on the job in hand rather than a guaranteed property: adhesion is an interface property of the construction and is qualified by trial on the customer's own substrate. |
| Scuff and abrasion resistance | Sutherland-type rub tester to ASTM D5264, at an agreed load, stroke count and receptor surface | The test for marking and scuffing, which is what conversion lines and handled panels actually complain about. Agree the load, the number of strokes and the receptor with the customer and run it on the finished construction, printed and coated as it will ship. Coefficient of friction to ASTM D1894 measures slip, which is a different property: use it to diagnose feeding, stacking and conveyor behaviour, not as the acceptance for scuff. |
Test methods
| Measurement | Method | What it tells you, and the usual acceptance |
|---|---|---|
| Wetting tension | ASTM D2578, or ISO 8296 test inks, or dyne pens at the press | The number that decides whether an ink can bond to a plastic or a metallised surface at all. 40 to 44 mN/m needed on PP, PE, PET, rigid PVC and styrene. Measure on the reel or pallet about to run, not on the treatment certificate, because corona decays and slip additive blooms in storage. The same pens read the surface energy of a cured ink film, which is what a coating, a foil or a glue has to wet. |
| Gloss | ISO 2813, 20 degree and 60 degree geometry | 55 +/- 10 GU at 20 degrees and 80 +/- 8 GU at 60 degrees on a printed solid on gloss coated board at 24 hours. 20 degrees is the discriminating angle on a high-gloss UV film; 60 degrees separates high-gloss films poorly and should not be used alone to settle a gloss dispute. |
| Solid ink density | ISO 5-3 Status E response with ISO 5-4 measurement geometry, no polarising filter | Black 1.75 to 1.90, cyan 1.40 to 1.50, magenta 1.40 to 1.50, yellow 1.20 to 1.30 on gloss coated stock at 1.2 g/m2. Always quote the status with the number: the same yellow reads about 0.95 to 1.10 on a Status T instrument. Wet and dry readings sit close together, because nothing evaporates and little penetrates. |
| UV dose and peak irradiance | Band-calibrated radiometer, UV-A 320 to 390 nm for mercury and 385 to 405 nm for LED, four-band head where short-wave loss is in question, no standard number cited | The only honest measure of what reached the ink. Run it through the press on a carrier sheet at running speed, per unit, and record both integrated dose in mJ/cm2 and peak irradiance in W/cm2, with the lamp rating in W/cm or the array wavelength and rating beside them. Peak irradiance is set by the source and its geometry and does not change with press speed; only the exposure time, and therefore the dose, changes. A mercury-calibrated head over-reads on an LED array and an LED-calibrated head is blind to the mercury short-wave lines, so the head must match the source. |
When the press-floor fixes have not worked